The need for performance standards for continuous glucose monitors.

نویسندگان

  • James H Nichols
  • David C Klonoff
چکیده

Self-monitoring blood glucose (SMBG) devices or glucose meters currently provide a means for patients to manage insulin dosing through intermittent monitoring of blood glucose levels several times a day, but newer continuous glucose monitor devices (CGM) offer the potential of real-time glucose monitoring with less pain and lower cost. Unlike SMBG devices that sample glucose levels in circulating blood, CGM samples from the interstitial fluid. CGM devices generate not only a single level, but through averaging with past glucose results, can predict future trends. While consensus guidelines exist for evaluating the agreement of SMBG devices to other glucose and laboratory methods, no guidelines currently exists for CGM devices. Standards are needed to define the performance of CGM devices, both in terms of spot accuracy and trend information, as well as the level of performance required for clinical management. The Diabetes Technology Society (DTS) has been in close communication on the development of CGM guidelines with the Food and Drug Administration (FDA) and the Clinical and Laboratory Standards Institute (CLSI). Development of standards for CGM devices if adopted by the FDA would set minimum requirements of performance for manufacturers to meet in producing CGM devices and define common terminology for the display and clinical utilization of CGM data. It is expected that CGM performance standards will advance over time as technology improves and consumer demands change. The development of CGM standards will also play an important role in accelerating the development of an artificial pancreas, which relies on CGM technology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The need for separate performance goals for glucose sensors in the hypoglycemic, normoglycemic, and hyperglycemic ranges.

Goals for Glucose Sensors in the Hypoglycemic, Normoglycemic, and Hyperglycemic Ranges B lood glucose monitors are an important tool for people with diabetes to assess their physiological status and allow them to properly dose themselves with medication or food. The need to adjust the amount of treatment is greatest when the blood glucose level is in the hypoglycemic range because of the risk o...

متن کامل

Measuring and reporting glycemic control in clinical trials: building a path to consensus

Clinical trials over time have used a variety of approaches for both measuring tight glycemic control and reporting results. The review by Finfer and colleagues in this issue of Critical Care is a step toward consensus within the research community to standardize the way blood glucose is measured and reported in clinical trials. The authors propose using specific measures of central tendency an...

متن کامل

Electromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors

Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, ho...

متن کامل

Analytical Performance and Quality Control of a Glucose Monitor System

  Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within...

متن کامل

New Criteria for Assessing the Accuracy of Blood Glucose Monitors meeting, October 28, 2011.

Glucose meters (GMs) are routinely used for self-monitoring of blood glucose by patients and for point-of-care glucose monitoring by health care providers in outpatient and inpatient settings. Although widely assumed to be accurate, numerous reports of inaccuracies with resulting morbidity and mortality have been noted. Insulin dosing errors based on inaccurate GMs are most critical. On October...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 1 1  شماره 

صفحات  -

تاریخ انتشار 2007