Optimization of 3D EPI technique for radio frequency (B1) field mapping at 3T
نویسندگان
چکیده
Introduction Spatial inhomogeneities in the radio-frequency (RF) field (B1) increase with field strength as the RF wavelength approaches the dimensions of the human head. B1 inhomogeneities pose various problems such as spurious signal and contrast changes in MRI, leading to bias in quantitative imaging and difficulties in tissue segmentation. Here, we optimize the 3D EPI B1 mapping method introduced by Jiru and Klose [1] that determines the local flip angle from the signal intensity of spin-echo (SE) and stimulatedecho (STE) images. With this method, inhomogeneities in the main static field (B0) lead to geometric distortions in the images and biased flip-angles due to off-resonance precession of the spins [2]. We present an extension of this approach using carefully chosen RF pulses and a post-processing procedure that corrects biased flip angles and image distortions along the phase direction. Methods Image acquisition: All data were acquired using a 3T whole-body Tim Trio system (Siemens Medical Solutions, Germany), operated with a body transmit coil and a 12-channel head-only receive coil. Distributions of B1 fields were determined on human subjects from 3D EPI acquisitions of SE (varied between 160 and 200) and STE pulses [1]. The resolution was 4x4x4 mm for an acquisition time of 2min 20s. Flip angle maps were normalized to the nominal flip angle (= 100%). An additional B0 map was also acquired for correction of image distortions and off-resonance spin precession effects (acquisition time of 2 min). Thresholding of the flip angle maps: High local B0 values lead to off-resonance precession of the spins and therefore to biased flip angle values in the B1 maps [2]. To determine the maximally tolerable local B0 value we acquired B1 maps on a gel phantom. Rectangular RF pulses were used with the shortest achievable duration (700us) to generate the SE and STE. An offset was added to the frequency of the RF pulses and varied within a range [-100 200] Hz, which corresponds to local B0 values present in the human head at 3T. At a voxel position where B0=0Hz, the maximum tolerable B0 value is the frequency at which the flip angle deviates by more than 5% error from the unbiased value (obtained with no offset frequency). We use this value in our post-processing procedure for thresholding of the B1 maps. Image post-processing: Artefactual voxel displacements along the phase encode direction (R->L) were corrected by unwarping the images based on the local B0 value [3]. Brain regions where the local B0 field was beyond our threshold value were masked out of the images and the missing flip angle values were estimated by averaging those of the remaining neighbouring voxels (padding). Results Figure 1 shows axial views of unsmoothed B1 maps. For demonstration purposes, the duration of the rectangular SE and STE RF pulses was set to 1400us. However, for all data presented in the following we used the shortest achievable RF duration (700us). Figure 1 a) shows a B1 map before post-processing. Figure 1b) shows the same flip angle map after unwarping along the R->L direction: the symmetry of the image is restored. However, strong artefactual B1 discontinuities remain in the Orbital Frontal Cortex (OFC) corresponding to high local B0field values (see figure 1c)). The maximum tolerable local B0 values can be seen in figure 2. In the human B1 maps, voxels where the local B0 value is beyond 110Hz were replaced using our padding procedure. The results are displayed in figure 3a), smoothed with an 8mm kernel. Discontinuities in the OFC region are no longer visible. For comparison, we show flip angle maps obtained using a reference ‘DAM’ method (figure 3c)) [4]. Results using both methods are within a 5% margin for all central regions of the brain. Repetitive acquisitions of 3D EPI B1 maps show instabilities below 3% across the brain volume (unshown). Conclusion Susceptibility gradients are shown to induce significant bias into flip angle maps due to off-resonance effects. However, we have shown that appropriate choice of RF pulses, unwarping of the images and interpolation of the affected voxels can correct for these artefacts. We were able to obtain reliable flip angle maps at 3T over the entire brain volume with a sufficient resolution and in an achievable experimental time. [1] F. Jiru and U. Klose, MRM 56:1375-1379 (2006). [2] J. Wang et al, MRM 56:463-468 (2006). [3] C. Hutton et al, NeuroImage 16:217-240 (2002). [4] J. Sled and G. Pike, MRM 43:589-593 (2000). Figure 1: a) Original flip angle map obtained using the 3D EPI method. b) Unwarped flip angle map. c) Corresponding B0-field map (in Hz). While unwarping of the images clearly improves image distortions, the flip angle biases remain. These occur where local B0-field values are high suggesting off-resonance effects as the source of these artefacts. 75 125 a) b)
منابع مشابه
Optimization and Validation of Methods for Mapping of the Radiofrequency Transmit Field at 3T
MRI techniques such as quantitative imaging and parallel transmit require precise knowledge of the radio-frequency transmit field (B(1) (+)). Three published methods were optimized for robust B(1) (+) mapping at 3T in the human brain: three-dimensional (3D) actual flip angle imaging (AFI), 3D echo-planar imaging (EPI), and two-dimensional (2D) stimulated echo acquisition mode (STEAM). We perfor...
متن کاملOptimization and group comparison of RF (B1) mapping methods at 3T
Introduction Spatial inhomogeneities in the radio-frequency (RF) field (B1) increase with field strength as the RF wavelength approaches the dimensions of the human head. B1 inhomogeneities pose various problems such as spurious signal and contrast changes in MRI, leading to bias in quantitative imaging and difficulties in tissue segmentation. Here, we optimize and compare three methods for fli...
متن کاملRobust and Fast Whole Brain Mapping of the RF Transmit Field B1 at 7T
In-vivo whole brain mapping of the radio frequency transmit field B(1) (+) is a key aspect of recent method developments in ultra high field MRI. We present an optimized method for fast and robust in-vivo whole-brain B(1) (+) mapping at 7T. The method is based on the acquisition of stimulated and spin echo 3D EPI images and was originally developed at 3T. We further optimized the method for use...
متن کاملRadio frequency (B1) field mapping at 7T using 3D SE/STE EPI technique
A. Lutti, C. Hutton, J. Stadler, O. Josephs, O. Speck, C. Tempelmann, J. Bernarding, and N. Weiskopf Wellcome Trust Centre for Neuroimaging, Institute of Neurology, University College London, London, United Kingdom, Special Lab Non-Invasive Brain Imaging, Leibniz Institute for Neurobiology, Magdeburg, Germany, Dept. Biomedical Magnetic Resonance, Institute for Experimental Physics, Otto-von-Gue...
متن کاملNo Inversion Double Angle Look-Locker (niDALL) for Flip Angle Mapping
Introduction: Transmit B1 inhomogeneity is a major problem at higher field strengths. The RF wavelength decreases with increasing field strength and at 3T and above begins to approach the same scale as the human body. This leads to destructive interference and non-uniform excitation of tissue. Methods exist for correcting this non-uniformity, but mapping the B1 field is a prerequisite. One meth...
متن کامل