Development of Josephson Voltage Standards

نویسندگان

  • Johannes Kohlmann
  • Ralf Behr
چکیده

Exciting applications of superconductivity are based on the macroscopic quantum state which exists in a superconductor. In this chapter we investigate the behaviour of junctions consisting of two weakly coupled superconductors. These junctions are nowadays called Josephson junctions1 (Josephson, 1962). The macroscopic quantum state results in an exceptional behaviour of these Josephson junctions. They are the basis for various applications in superconductive electronics (cf. Anders et al, 2010), e.g. in the field of metrology for highprecision measurements. The most significant representative of a metrological application is the Josephson voltage standard. This quantum standard enables the reference of the unit of voltage, the volt, just to physical constants. It is nowadays used in many laboratories worldwide for high-precision voltage measurements. The main component of each modern Josephson voltage standard is the highly integrated series array consisting of tens of thousands of Josephson junctions fabricated in thin-film technology. While Josephson junctions are conceptually simple, nearly 50 years of developments were needed to progress from single junctions delivering a few millivolt at most to highly integrated series arrays containing more than 10,000 or even 100,000 junctions. These large series arrays enable the generation of dc and ac voltages at the 10 V level, which is relevant for most applications. Conventional Josephson voltage standards based on underdamped Josephson junctions are used for dc applications. The increasing interest in highly precise ac voltages has stimulated different attempts to develop measurement tools on the basis of Josephson arrays for ac applications, namely programmable Josephson voltage standards containing binary-divided arrays and pulse-driven Josephson voltage standards both based on overdamped Josephson junctions. This chapter describes the development of these modern dc and ac Josephson voltage standards as well as their fundamentals and applications. The development and use of Josephson voltage standards have also been described recently in several review papers (amongst others: Niemeyer, 1998; Hamilton, 2000; Yoshida, 2000; Behr et al., 2002; Kohlmann et al., 2003; Benz & Hamilton, 2004; Jeanneret & Benz, 2009).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Josephson Voltage Standards of the PTB and the BIPM

A comparison of the Josephson array voltage standards of the Bureau International des Poids et Mesures (BIPM) and the Physikalisch-Technische Bundesanstalt (PTB), Braunschweig, Germany, was carried out in October 2014 at the level of 10 V. For this exercise, options A and B of the BIPM.EM-K10.b comparison protocol were applied. Option B required the BIPM to provide a reference voltage for measu...

متن کامل

Operation of NIST Josephson Array Voltage Standards

This paper begins with a brief discussion of the physical principles and history of Josephson effect voltage standards. The main body of the paper deals with the practical details of the array design, cryoprobe construction, bias source requirements, adjustment of the system for optimum performance, calibration algorithms, and an assessment of error sources for the NIST-developed Josephson arra...

متن کامل

Perspectives of Overdamped Josephson Junctions in Voltage Standard Applications

We discuss the main characteristics that must be satisfied by Josephson junctions for metrological applications and, specifically, in the development of voltage standards of new generation. Data reported in the literature for the most established technologies, like SNS (Superconductor-Normal conductor-Superconductor), SINIS (SuperconductorInsulator-Normal conductor-Insulator-Superconductor) and...

متن کامل

Josephson Voltage Standards Comparison between Cenam and Nist at 10 V Level

Abstract: A comparison of Josephson Voltage Standards (JVS) between the National Institute of Standards and Technology (NIST) and the Centro Nacional de Metrología (CENAM) held at CENAM from 21 to 23 of March 2006 is reported. The comparison was made at the 10 V level by measuring four Zener references using the JVS of CENAM and the transportable Compact Josephson Voltage Standard (CJVS) of NIS...

متن کامل

DC Voltage Linearity Measurements and DVM Calibration with Conventional and Programmable Josephson Voltage Standards

Traditional calibration of dc voltage high accuracy digital voltmeters (DVMs) using conventional and Programmable Josephson Voltage Standards at INMETRO show improvements between 73.7 % and 98.3 % when compared with a regular calibration technique. Some calibration results as well as DVM linearity and gain drift analysis (up to 10 V range) are presented and discussed in this paper.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012