Nano-level Monitoring of Yttrium by a Novel PVC-membrane Sensor Based on 2,9-dihydroxy-1,10-diphenoxy-4,7-dithiadecane
نویسندگان
چکیده
A poly (vinyl chloride)-based membrane of 2,9-dihydroxy-1,10-diphenoxy-4,7-dithiadecane (C20H26O4S2) as a neutral carrier was prepared and investigated as an Y-selective electrode. Effects of various plasticizers and anion excluders were studied in detail and improved performance was observed. The best performance was obtained for the membrane sensor having a composition of L: PVC: NPOE: PA in the ratio of 2:30:62:6 (mg). The performance of the membrane was found to be the following: A Nernstian slope of 20.0 ± 0.2 mV per decade across a broad range (1.0 × 10 to 1.0 × 10 mol dm); a detection limit of 2.14 × 10 mol dm between the pH = 4.5 and 9.0; additionally, the response time was about 15 s; good Y selectivity over a wide variety of other metal ions. The membrane sensor was applied as an indicator electrode in potentiometric titration of fluoride ion and also used for determination of F ion in tap water and toothpaste samples. (doi: 10.5562/cca1937)
منابع مشابه
Novel ZrO2 ion-selective electrode based on 4,7,13,16,21,24-hexa oxa- 1,10- diazabicyc1o[8,8,8]-hexa cosane as neutral carrier in PVC matrix
In this work, a novel Zr02+ PVC-based membrane sensor based on 4,7,13,16,21,24-hexa oxa-1,10- diazabicyclo[8,8,8]- hexa cosane (HODBHC) as a new ionophore is presented. The sensor displays a linear dynamic rangebetween 1.0x 10-1 and 1.0x10 6 M, with a near Nernstian slope of 29.9 ± 0.4 mV per decade in an acidic solution(pH=1). The limit of detection is 8.0 x 1 0 7 M. The electrodes possess adv...
متن کاملDesign of a Selective and Sensitive PVC-Membrane Potentiometric Sensor for Strontium Ion Based on 1,10-Diaza-5,6-benzo-4,7-dioxacyclohexadecane-2,9-dione as a Neutral Ionophore
A novel PVC membrane sensor for the Sr ion based on 1,10-diaza-5,6-benzo-4,7dioxacyclohexadecane-2,9-dione has been prepared. The sensor possesses a Nernstian slope of 30.0 ± 0.6 mV decade over a wide linear concentration range of 1.6 × 10-3.0 ×10 M with a detection limit of 6.3 ×10 M. It has a fast response time of <15 s and can be used for at least two months without any considerable divergen...
متن کاملA novel sensor based on a heterocyclic ionophore for cerium (III) analysis in real samples
A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7 M. It has a fast response time (5 s) and can be used for two m...
متن کاملPerformance Evaluation of a Novel Potentiometric Membrane Sensor for Determination of Atorvastatin in Pharmaceutical Preparations
A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09–5586 µ...
متن کاملComparison of new optical sensor based on triazene ligand immobilized on PVC and triacetylcellulose membranes for Hg (II) Ion
For spectrophotometric analysis of Hg (II) ions, we have used and compared two membranes preparation methods using different polymer; one is poly(vinyl chloride) (PVC) and the other is triacetylcellulose (TAC). In the case of TAC membrane, it was treated with a ligand solution (1.166 × 10-3 mole L-1) in ethylenediamine at the ambient temperature for almost 2-5 min. However, in the case of PVC m...
متن کامل