Determination of designer drug cross-reactivity on five commercial immunoassay screening kits.
نویسندگان
چکیده
The detection of new designer drugs is often a difficult issue in forensic urine drug testing as immunoassays are the primary screening methodology for drugs of abuse in many of these laboratories. Cross-reactivity of compounds with immunoassay kits can either aid or complicate the detection of a variety of drug and drug metabolites. For instance, emerging designer drugs that share structural similarities to amphetamines and phencyclidine (PCP) have the potential to cross-react with assays designed to detect these compounds. This study evaluates the cross-reactivity of five commercially available immunoassay reagent kits for 94 designer drugs on a Roche/Hitachi Modular P automated screening instrument. The compounds used in this study are grouped by structural class as follows: 2,5-dimethoxyamphetamines, 2C (2,5-dimethoxyphenethylamines), β-keto amphetamines, substituted amphetamines, piperazines, α-pyrrolidinopropiophenones, tryptamines and PCP analogs. A drug concentration of 100 µg/mL was used to determine cross-reactivity for each assay and resulted in the following positive rates: Microgenics DRI(®) Ecstasy enzyme assay (19%), Microgenics DRI(®) Phencyclidine enzyme assay (20%), Lin-Zhi Methamphetamine enzyme immunoassay (39%), Siemens/Syva(®) EMIT(®)II Plus Amphetamines assay (43%) and CEDIA(®) DAU Amphetamine/Ecstasy assay (57%). Of the 94 designer drugs tested, 14% produced a negative response for all five kits. No designer drug used in this study generated a positive result for all five immunoassay kits.
منابع مشابه
Cross-reactivity of monomeric and dimeric biosynthetic human growth hormone in commercial immunoassays.
Commercial kits give different measurements for concentrations of growth hormone (GH, somatotropin) in serum. Most notably, a two-site monoclonal-antibody-based immunoradiometric assay (IRMA) from Hybritech routinely yields lower values than do conventional RIAs in which polyclonal antibodies are used. We used purified dimeric biosynthetic human GH as a model compound to investigate the specifi...
متن کاملCross-reactivity of designer drugs, including cathinone derivatives, in commercial enzyme-linked immunosorbent assays.
Since the introduction of synthetic heroin, designer drugs have been increasing in prevalence in the United States drug market over the past few decades. Recently, 'legal highs' sold as 'bath salts' have become a household term for one such class of designer drugs. While a number of federal and state bans have been enacted, the abuse of these designer drugs still continues. Few assays have been...
متن کاملUsing cheminformatics to predict cross reactivity of “designer drugs” to their currently available immunoassays
BACKGROUND A challenge for drug of abuse testing is presented by 'designer drugs', compounds typically discovered by modifications of existing clinical drug classes such as amphetamines and cannabinoids. Drug of abuse screening immunoassays directed at amphetamine or methamphetamine only detect a small subset of designer amphetamine-like drugs, and those immunoassays designed for tetrahydrocann...
متن کاملEvaluation of five commercial assays for the detection of anti-dsDNA antibodies: three Crithidia luciliae indirect immunofluorescence test kits and two enzyme immunoassay kits.
OBJECTIVE There are various methods for anti-dsDNA detection. Crithidia luciliae indirect immunofluorescence test (CLIFT) and enzyme immunoassay (EIA) are the most commonly used at present. A number of CLIFT and EIA kits are commercially available. The objective of the present study was to evaluate the diagnostic performance of three commercial CLIFT kits, two commercial EIA kits, and their com...
متن کاملComparison of two commercial microimmunofluorescence kits and an enzyme immunoassay kit for detection of serum immunoglobulin G antibodies to Chlamydia pneumoniae.
We compared the MRL and the Labsystems Chlamydia pneumoniae microimmunofluorescence (MIF) immunoglobulin G (IgG) kits and the Labsystems enzyme immunoassay (EIA) kit in a blinded study of 83 serum samples in which we evaluated titers, cross-reactivity to other species, and reproducibility. There was no statistically significant difference between the MRL and the Labsystems MIF kits in the endpo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of analytical toxicology
دوره 39 2 شماره
صفحات -
تاریخ انتشار 2015