How transfer rates generate Gd-BOPTA concentrations in rat liver compartments: implications for clinical liver imaging with hepatobiliary contrast agents.

نویسنده

  • Catherine M Pastor
چکیده

Following the injection of hepatobiliary contrast agents, MRI detects all molecules included in a region of interest but cannot estimate true concentrations in sinusoids, interstitium, hepatocytes or bile canaliculi. The aim of the study was to measure true concentrations in hepatocytes and to show how transfer rates across sinusoidal and canalicular membranes generate these concentrations. We perfused livers isolated from normal rats with 200 μM Gd-DTPA and Gd-BOPTA and measured clearances from sinusoids to liver and from hepatocytes to bile canaliculi or back to interstitium. We detected Gd-BOPTA with a gamma probe and determined true concentrations in each liver compartment knowing their liver volumes. No pharmacokinetic modelling was applied. Gd-BOPTA clearance from sinusoids to liver (2.5 ± 0.4 mL/min) was 50 times higher than that of Gd-DTPA (0.05 ± 0.02 mL/min) when portal flow rate was 30 mL/min (p < 0.0001). Gd-BOPTA clearance from sinusoids to liver was always superior to hepatocyte clearance, and hepatocyte Gd-BOPTA concentrations measured by the probe increased over time. Gd-BOPTA concentrations reached 439 ± 83 μM in hepatocytes and 15 × 700 ± 3100 μM in bile canaliculi, while concentrations in sinusoids were 200 μM. Gd-BOPTA true concentrations in hepatocytes depend on the simultaneous clearances from sinusoids to hepatocytes and from hepatocytes to bile canaliculi and back to sinusoids. The study better defines how signal intensities are generated when hepatobiliary contrast agents are injected in clinical imaging. Copyright © 2016 John Wiley & Sons, Ltd.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

How organic anions accumulate in hepatocytes lacking Mrp2: evidence in rat liver.

In the liver, the accumulation of hepatobiliary contrast agents is a crucial issue to understand the images of liver scintigraphy or magnetic resonance (MR) imaging. Thus, depending on the regulation of uptake and exit membrane systems in normal and injured hepatocytes, these contrast agents will accumulate differently within cells. Gadobenate dimeglumine (Gd-BOPTA) is a hepatobiliary MR contra...

متن کامل

Quantification of Gd-BOPTA uptake and biliary excretion from dynamic magnetic resonance imaging in rat livers: model validation with 153Gd-BOPTA.

OBJECTIVES We sought to develop and validate a pharmacokinetic model allowing description of the magnetic resonance (MR) signal intensity induced by the hepatobiliary contrast agent Gd-BOPTA and to quantify the overall Gd-BOPTA transport in rat liver. MATERIALS AND METHODS MR signal intensity was recorded during the perfusion of rat livers with Gd-DTPA, an extracellular contrast agent, and Gd...

متن کامل

Comparison of gadobenate dimeglumine and gadopentetate dimeglumine: a study of MR imaging and inductively coupled plasma atomic emission spectroscopy in rat brain tumors.

BACKGROUND AND PURPOSE After the advent of extracellular contrast media, hepatobiliary-specific gadolinium chelates were developed to improve the diagnostic value of MR imaging of the liver. Gadobenate dimeglumine (Gd-BOPTA) is a new paramagnetic contrast agent with partial biliary excretion that produces prolonged enhancement of liver parenchyma on T1-weighted images. However, whether Gd-BOPTA...

متن کامل

Comparison of Gd-Bz-TTDA, Gd-EOB-DTPA, and Gd-BOPTA for dynamic MR imaging of the liver in rat models.

To evaluate the competitive potential of a new lipophilic paramagnetic complex, Gd-Bz-TTDA [4-benzyl-3,6,10-tri (carboxymethyl)-3,6,10-triazado-decanedioic acid] compared with two other commercially available MR hepatobiliary contrast agents, gadobenate dimeglumine (Gd-BOPTA) and gadoxetic acid (Gd-EOB-DTPA), dynamic MR imaging studies were performed on normal and hepatocellular carcinoma (HCC)...

متن کامل

Contrast-enhanced magnetic resonance cholangiography with Gd-BOPTA and Gd-EOB-DTPA in healthy subjects.

PURPOSE To evaluate the biliary enhancement dynamics of the two gadolinium chelates Gd-BOPTA (MultiHance) and Gd-EOB-DTPA (Primovist) in normal healthy subjects. MATERIAL AND METHODS Ten healthy volunteers were evaluated with both agents by magnetic resonance (MR) imaging at 1.5T using a breath-hold gradient-echo T1-weighted VIBE sequence. The relative signal intensity (SI) differences betwee...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Contrast media & molecular imaging

دوره 11 4  شماره 

صفحات  -

تاریخ انتشار 2016