An assessment of template-guided implant surgery in terms of accuracy and related factors
نویسندگان
چکیده
PURPOSE Template-guided implant therapy has developed hand-in-hand with computed tomography (CT) to improve the accuracy of implant surgery and future prosthodontic treatment. In our present study, the accuracy and causative factors for computer-assisted implant surgery were assessed to further validate the stable clinical application of this technique. MATERIALS AND METHODS A total of 102 implants in 48 patients were included in this study. Implant surgery was performed with a stereolithographic template. Pre- and post-operative CTs were used to compare the planned and placed implants. Accuracy and related factors were statistically analyzed with the Spearman correlation method and the linear mixed model. Differences were considered to be statistically significant at P≤.05. RESULTS The mean errors of computer-assisted implant surgery were 1.09 mm at the coronal center, 1.56 mm at the apical center, and the axis deviation was 3.80°. The coronal and apical errors of the implants were found to be strongly correlated. The errors developed at the coronal center were magnified at the apical center by the fixture length. The case of anterior edentulous area and longer fixtures affected the accuracy of the implant template. CONCLUSION The control of errors at the coronal center and stabilization of the anterior part of the template are needed for safe implant surgery and future prosthodontic treatment.
منابع مشابه
A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry.
INTRODUCTION The aim of this systematic review was to analyze the dental literature regarding accuracy and clinical application in computer-guided template-based implant dentistry. MATERIALS AND METHODS An electronic literature search complemented by manual searching was performed to gather data on accuracy and surgical, biological and prosthetic complications in connection with computer-guid...
متن کاملA survey of the satisfaction of patients who have undergone implant surgery with and without employing a computer-guided implant surgical template
PURPOSE This study aims to investigate the degree of subjective pain and the satisfaction of patients who have undergone an implant treatment using a computer-guided template. MATERIALS AND METHODS A survey was conducted for 135 patients who have undergone implant surgery with and without the use of the computer-guided template during the period of 2012 and 2013 in university hospitals, denta...
متن کاملUnplanned Operations and Adverse Events after Surgery for Diaphyseal Fracture of the Clavicle
Background: We used a database of patients treated at three hospitals to study the primary null hypothesis that thereare no factors associated with unplanned reoperations or adverse events after surgical repair for diaphyseal claviclefracture. Additionally we addressed the following secondary study questions: 1. What is the prevalence of unplannedreoperations or adverse events...
متن کاملAccuracy in computer-aided implant surgery--a review.
The objective of this article was to review the different factors and limitations influencing the accuracy of computer-aided implant surgery. In vitro and in vivo accuracy studies of articles and congress proceedings were examined. Similar results using bur tracking as well as image-guided template production techniques have been reported, and both methods allow for precise positioning of denta...
متن کاملThe Use of Eponyms for Surgical Approaches and Fractures in Elbow Surgery: Accuracy and Reliability Pre- and Post-Training
The use of eponymous terms in orthopedic trauma surgery is common. In an assessment pre-training versus posttrainingat an AO Advanced Elbow Trauma Course, we aimed to report on (1) the accuracy and (2) reliability of 10common eponymous terms used for surgical approaches and fractures in elbow surgery. Before training, eponymswere described correctly in 38% of questions versus 47% after training...
متن کامل