Implantation of subcutaneous implantable cardioverter defibrillators in Europe: results of the European Heart Rhythm Association survey.
نویسندگان
چکیده
AIMS The purpose of this European Heart Rhythm Association (EHRA) survey is to provide an overview of the current use of subcutaneous cardioverter defibrillators (S-ICDs) across a broad range of European centres. METHODS AND RESULTS A questionnaire was sent via the internet to centres participating in the EHRA electrophysiology research network. Questions included standards of care and policies used for patient management, indications, and techniques of implantation of the S-ICDs. In total, 52 centres replied to the questionnaire. More than one-fourth of the responding centres does not implant the S-ICD (n = 14, 27%). The majority reported to have implanted <10 (50%) or 10-29 (23%) S-ICDs during the last 12 months. Lack of reimbursement (25%), non-availability (19%), and cost of the device (25%) seem to limit the use of the S-ICD. The most commonly reported indications for S-ICD implantation are a difficult vascular access (82%), a history of previous complicated transvenous ICD (8O%), young age (69%), or an anticipated higher risk of infection (63%). Inappropriate therapies were the most frequently reported major problems (38%), but the majority of respondents (51%) never encountered any issue after an S-ICD implantation. Most of the respondents (83%) anticipate significant increase of S-ICD use within the next 2 years. CONCLUSION This survey provides a contemporary insight into S-ICD implantation and management in the European electrophysiology centres, showing different approaches, depending on local policies. Cost issues or lack of reimbursement strongly influence the dissemination of the device. However, most respondents retain that S-ICD use will significantly increase in a very short time.
منابع مشابه
Preferred tools and techniques for implantation of cardiac electronic devices in Europe: results of the European Heart Rhythm Association survey.
The aim of this European Heart Rhythm Association (EHRA) survey was to assess clinical practice in relation to the tools and techniques used for cardiac implantable electronic devices procedures in the European countries. Responses to the questionnaire were received from 62 members of the EHRA research network. The survey involved high-, medium-, and low-volume implanting centres, performing, r...
متن کاملHow are arrhythmias detected by implanted cardiac devices managed in Europe? Results of the European Heart Rhythm Association Survey.
The management of arrhythmias detected by implantable cardiac devices can be challenging. There are no formal international guidelines to inform decision-making. The purpose of this European Heart Rhythm Association (EHRA) survey was to assess the management of various clinical scenarios among members of the EHRA electrophysiology research network. There were 49 responses to the questionnaire. ...
متن کاملRemote monitoring of cardiac implantable electronic devices in Europe: results of the European Heart Rhythm Association survey.
The aim of this European Heart Rhythm Association survey was to provide an insight into the current use of remote monitoring for cardiac implantable electronic devices in Europe. The following topics were explored: use of remote monitoring, infrastructure and organization, patient selection and benefits. Centres using remote monitoring reported performing face-to-face visits less frequently. In...
متن کاملReplacement of implantable cardioverter defibrillators and cardiac resynchronization therapy devices: results of the European Heart Rhythm Association survey.
The aim of this EP Wire was to assess the management, indications, and techniques for implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT) device replacement in Europe. A total of 24 centres in 14 European countries completed the questionnaire. All centres were members of the European Heart Rhythm Association Electrophysiology Research Network. Replacement pr...
متن کاملManagement of patients with ventricular tachycardia in Europe: results of the European Heart Rhythm Association survey.
The purpose of this European Heart Rhythm Association (EHRA) survey was to assess clinical practice in the management of ventricular tachycardia (VT). The data are based on an electronic questionnaire sent to the members of the EHRA Research Network. Responses were received from 31 centres in 16 countries. The results of the survey show that the management of VT is in general in accordance with...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
دوره 18 9 شماره
صفحات -
تاریخ انتشار 2016