The 'mirror test' for estimating visual acuity in infants.

نویسندگان

  • Richard Bowman
  • Daphne L McCulloch
  • Elizabeth Law
  • Karen Mostyn
  • Gordon N Dutton
چکیده

OBJECTIVE The authors aimed to investigate the association between the distance at which infants fixate their own reflections and visual acuity card testing, and to determine whether this could form the basis of a new clinical test of visual function in infants. METHODS 78 healthy infants under 9 months of age (range 1-266 days, mean 56.5+/-64SD) were recruited and held close to a mirror such that they attended their own reflections. The distance from the mirror was increased until they no longer held fixation. Binocular acuities were tested with the Teller acuity card procedure. RESULTS Reliability was rated 'good' in 58 and 60 infants respectively, for mirror distances and for the acuity cards. Data were also included for moderate reliability (n=20 and 14 respectively). The mean mirror distance was 54.9 cm (range 13.5-178, SD=42.8). The mean Teller acuity was 2.19 cycles per degree (range 0.2-14.5, SD=2.8). (Snellen equivalent 6/82, range 6/900-6/12). Mirror distance showed linear correlation with both Teller acuity (R(2)=0.69, p<0.0005) and with age (R(2)=0.73, p<0.0005) by univariate analysis. Using multivariate analysis, only age retained significance. Using logarithmic scales and a logistic growth function for age, correlations were stronger (log mirror distance vs log Teller acuity, R(2)=0.86, p<0.0005; logistic regression of log mirror distance vs log age, R(2)=0.88, p<0.0005), and both retained independent significance in a multivariate model. CONCLUSION Mirror fixation distance increases with age in infants and has a good correlation with acuity card results. The portability and ease of use would make it a useful additional tool for detecting impaired visual function in infants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی مقایسه‌ای حدت بینایی و حساسیت به کنتراست در رانندگان مراجعه‌کننده به درمانگاه چشم‌ بیمارستان فرشچیان همدان

Background and Objective: Car accidents are the second leading cause of mortality in Iran. For safe driving, drivers require minimum acceptable visual acuity. In Iran, the accepted routine test to take driving license is Snellen vision chart, which is not adequate for visual acuity determination in real and natural environment. It seems that introducing a more sensitive and specific screening t...

متن کامل

Investigation of visual acuity and residual refractive error after cataract surgery in patients with senile cataract by phacoemulsification

Background and Aim: Vision improvement and reduction of refractive errors are considered as important goals of cataract surgery. The purpose of this study was to evaluate residual refractive errors after cataract surgery in the patients with senile cataract in Shahid Rahimi Hospital in Khorramabad City between 2017 and 2018. Material and Methods: This cross-sectional study included 178 patients...

متن کامل

A Quantitative Investigation on the Effect of Edge Enhancement for Improving Visual Acuity at Different Levels of Contrast

Background: The major limitation in human vision is refractive error. Auxiliary equipment and methods for these people are not always available. In addition, limited range of accommodation in adult people when switching from a far point to a near point is not simply possible. In this paper, we are looking for solutions to use the facilities of digital image processing and displaying to improve ...

متن کامل

SIGMA: A Serious Game Based on a New Approach to Improving Visual Acuity in Children with Laze Eye(Amblyopia)

Background and Aim: One of the main reasons of blindness, Unilateral vision weakness in children, adolescents and middle aged people is Amblyopia. The goal of this project is to design and production of a serious game to treating Amblyopia and to investigate the effects of this method in children's. Materials and Methods: In this Interactive analysis, 60 people suffering from Unilateral Amblyo...

متن کامل

Automated measurement of resolution acuity in infants using remote eye-tracking.

PURPOSE To validate a novel, automated test of infant resolution acuity based on remote eye-tracking. METHODS Infants aged 2 to 12 months were tested binocularly using a new adaptive computerized test of infant vision using eye tracking (ACTIVE), and Keeler infant acuity cards (KIAC). The ACTIVE test ran automatically, using remote eye-tracking to assess whether the infant fixated a black-and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 94 7  شماره 

صفحات  -

تاریخ انتشار 2010