On-line Capillary Separations/Tandem Mass Spectrometry for Protein Digest Analysis by Using an Ion Trap Storage/Reflectron Time-of- Flight Mass Detector

نویسندگان

  • Jing-Tao Wu
  • Ling He
  • Michael X. Li
  • Steve Parus
چکیده

Capillary separations interfaced to tandem mass spectrometry provide a very powerful tool for the characterization of biological macromolecules such as proteins and peptides. The development of real time data-dependent data acquisition has further enhanced the capability of this method. However, the application of this technique to fast capillary separations has been limited by the relatively slow spectral acquisition speed available on scanning mass spectrometers. In this work, an ion trap storage/reflectron time-of-flight mass spectrometer (IT/reTOFMS) has been used as an on-line tandem mass detector for capillary high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE) separations of peptide mixtures including a protein digest. By taking advantage of the nonscanning property of the time-offlight mass spectrometer, a fast spectral acquisition rate has been achieved. This fast spectral acquisition rate, combined with a new protocol that speeds up tickle voltage optimization, has provided MS/MS spectra for multiple components in a hemoglobin digest during one liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS) run. Further, the IT/ reTOF-MS has the speed to provide MS/MS spectra for multiple components in a CE separation of a synthetic peptide mixture within one CE/MS/MS run. (J Am Soc Mass Spectrom 1997, 8, 1237-1246) © 1997 American Society for Mass Spectrometry

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Use of On-line Capillary Electrophoresis/Electrospray Ionization with Detection via an Ion Trap Storage/Reflection Time-of-flight Mass Spectrometer for Rapid Mutation-site Analysis of Hemoglobin Variants

Capillary electrophoresis/electrospray ionization using an ion trap storage/reflectron time-of-flight mass spectrometer detector (CE/ESI-IT/reTOF) is used to provide a rapid and sensitive method for analyzing structural variants in the hemoglobin (Hb) â-chain. The Hb αand â-chains are separated and the â-chain is digested by trypsin. The digest is analyzed by CE/ESI-IT/reTOF where a comparison ...

متن کامل

On-line capillary electrophoresis/microelectrospray ionization-tandem mass spectrometry using an ion trap storage/time-of-flight mass spectrometer with SWIFT technology.

The development of a system capable of the speed required for on-line capillary electrophoresis-tandem mass spectrometry (CE-MS/MS) of tryptic digests is described. The ion trap storage/reflectron time-of-flight (IT/reTOF) mass spectrometer is used as a nonscanning detector for rapid CE separation, where the peptides are ionized on-line using electrospray ionization (ESI). The ESI produced ions...

متن کامل

Identification of proteins from two-dimensional gel electrophoresis of human erythroleukemia cells using capillary high performance liquid chromatography/electrospray-ion trap-reflectron time-of-flight mass spectrometry with two-dimensional topographic map analysis of in-gel tryptic digest products.

Protein spots from two-dimensional (2-D) gel electrophoresis of a human erythroleukemia cell line have been identified by analysis of the in-gel tryptic digests using capillary high performance liquid chromatography (HPLC) separation with on-line detection using electrospray ionization mass spectrometry (ESI-MS). This is performed using an electrospray/ion trap storage/reflectron time-of-flight...

متن کامل

Development of a capillary high-performance liquid chromatography tandem mass spectrometry system using SWIFT technology in an ion trap/reflectron time-of-flight mass spectrometer.

In this work a capillary high-performance liquid chromatography/tandem mass spectrometry system has been developed in a quadrupole ion trap/reflectron time-of-flight mass spectrometer. The broadband excitation for isolating a precursor ion is achieved by generating the stored waveform inverse Fourier transform waveform in real time. Following the isolation and cooling periods, an auxiliary AC v...

متن کامل

An ion trap storage/time-of-flight mass spectrometer

An ion trap/time-of-flight (TOF) mass spectrometer combination has been developed in order to combine the storage capabilities of an ion trap with the speed and resolution of a time-of-flight device. The ion trap is an rf quadrupole trap which operates in the total storage mode, i.e., with the dc voltage=0 on the end caps and rf voltage on the ring electrode. The trap has an ion storage time of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005