Two-point motional Stark effect diagnostic for Madison Symmetric Torus.

نویسندگان

  • J Ko
  • D J Den Hartog
  • K J Caspary
  • E A Den Hartog
  • N A Pablant
  • H P Summers
چکیده

A high-precision spectral motional Stark effect (MSE) diagnostic provides internal magnetic field measurements for Madison Symmetric Torus (MST) plasmas. Currently, MST uses two spatial views--on the magnetic axis and on the midminor (off-axis) radius, the latter added recently. A new analysis scheme has been developed to infer both the pitch angle and the magnitude of the magnetic field from MSE spectra. Systematic errors are reduced by using atomic data from atomic data and analysis structure in the fit. Reconstructed current density and safety factor profiles are more strongly and globally constrained with the addition of the off-axis radius measurement than with the on-axis one only.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved spectral analysis for the motional Stark effect diagnostic.

The magnetic pitch angle and the magnitude from reversed field pinch plasmas in the Madison symmetric torus (MST) have been routinely obtained from fully resolved motional Stark effect (MSE) spectrum analyses. Recently, the spectrum fit procedure has been improved by initializing and constraining the fit parameters based on the MSE model in the atomic data and analysis structure. A collisional-...

متن کامل

Advances in neutral-beam-based diagnostics on the Madison Symmetric Torus reversed-field pinch „invited..

Innovative charge-exchange recombination spectroscopy !CHERS", motional Stark effect !MSE", and Rutherford scattering diagnostics are now in operation on the Madison Symmetric Torus !MST" reversed-field pinch !RFP". The CHERS diagnostic measures impurity ion flow and temperature, localized to 2 cm with high time resolution !#100 kHz". A spectral MSE diagnostic has been in use for five years, me...

متن کامل

Note: Multi-point measurement of |B| in the gas-dynamic trap with a spectral motional Stark effect diagnostic.

An upgraded spectral motional Stark effect diagnostic has been installed on the gas-dynamic trap (GDT) experiment to enable spatially resolved measurement of |B|. A new low-noise charge-coupled device detector, combined with enhancements of the diagnostic neutral beam, allows single-shot profile measurements. Previously only single-point motional Stark effect measurements were possible, and det...

متن کامل

High-speed three-wave polarimeter-interferometer diagnostic for Madison symmetric torus

A high-speed three-wave polarimeter-interferometer diagnostic has been developed on the Madison symmetric torus reversed field pinch to provide simultaneous measurement of electron density and poloidal magnetic field profile evolution. With increased digitizer bandwidth, polarimetry noise due to aliasing and cross-talk is minimized, and time response improved. System performance is demonstrated...

متن کامل

A diagnostic neutral beam system for the MST reversed-field pinch

A diagnostic neutral beam system has been developed for the Madison symmetric torus ~MST! reversed-field pinch. The system is primarily used: ~1! for measurement of the majority ion equilibrium and fluctuating velocity and temperature by Rutherford scattering ~RS!; ~2! for measurement of the impurity ion velocity and temperature, both equilibrium and fluctuating, by charge-exchange recombinatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 81 10  شماره 

صفحات  -