Ultraviolet detection of amino acids based on their on-column conjugation with cupric cation using a disposable electrophoresis microdevice.

نویسندگان

  • Chun Zhai
  • Jin Sheng
  • Wei Qiang
  • Jianping Lei
  • Huangxian Ju
چکیده

A method for fast sensitive ultraviolet detection of amino acids was developed with a disposable electrophoresis microdevice. The microdevice was conveniently constructed by fixing a fused-silica capillary with a sampling fracture to a printed circuit board. During the separation process, the on-column conjugation of amino acids with cupric cation led to the ultraviolet absorption at 232 nm that could be directly used for fast analysis of amino acids. Using 20 mM boric acid (pH 5.3) containing 5 mM cupric cation and 0.015% Tween 20 as running buffer, this method could completely separate lysine, glutamine and serine at a sampling time of 2 s at +210 V and a separation voltage of +1800 V (240 V/cm). The theoretical plate numbers were from 140,000 to 205,000 plates/m. The linear ranges were from 10 to 500 microM for lysine, 20-1000 microM for glutamine and serine. The novel protocol had been successfully used to detect amino acids in beverage samples with recovery more than 85.0%, indicating its advantages and potential analytical application in different fields.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Catalytic Effects of Carbon Nanotubes on Complexation of Some Amino Acids via Cobalt Cation Catalyst

In this research, investigation of the adsorption isotherms and the effect of solution conditions such as pH and concentration of complexation of some amino acids with cobalt(II) nitrate six-hydrate upon multi-wall type carbon nanotube (CNT) were done. The adsorption capacity of complexation of amino acids onto the surface of carbon nanotube increased with the pH from acidic to alkaline. At pH ...

متن کامل

Development and evaluation of a microdevice for amino acid biomarker detection and analysis on Mars.

The Mars Organic Analyzer (MOA), a microfabricated capillary electrophoresis (CE) instrument for sensitive amino acid biomarker analysis, has been developed and evaluated. The microdevice consists of a four-wafer sandwich combining glass CE separation channels, microfabricated pneumatic membrane valves and pumps, and a nanoliter fluidic network. The portable MOA instrument integrates high volta...

متن کامل

Effect of Various Levels of Protein in Diet Based on Total and Digestible Amino Acids on Performance of Cobb Strain Broilers

In order to study the effects of various levels of protein in diet based on total and digestible amino acids on performance and carcass traits of broilers, an experiment was conducted as a completely randomized design with 288 broiler chicks from Cobb 500 strain in 6 treatments, each treatment consist of 3 replicates with 16 chicks per replicate. Treatments were the diets as follow: 1) diet for...

متن کامل

Analysis of Plasma Amino Acids Using RP-HPLC and Pre-Column Derivatization with OPA/3-MPA

ABSTRACT        Background and Objective: Measurement of amino acids is an important tool for metabolic studies and evaluation of patients’ clinical condition. The aim of this study was to analyze the plasma amino acids using reverse phase high performance liquid chromatography techniques (RP-HPLC) with pre-column derivatization by o-phthalaldehyde (OPA)...

متن کامل

Chiral separation of NBD-amino acids by ligand-exchange micro-channel electrophoresis.

The chiral separation of amino acid derivatives by ligand-exchange electrophoresis in a microchannel chip was performed for the first time. A Cu(II) complex with L-prolinamide was used as a chiral selector. The migration behaviors of eleven NBD-DL-amino acids were investigated by ligand-exchange capillary electrophoresis (LE-CE). The enantiomer of five NBD-amino acids (Ser, Thr, Val, Phe and Hi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 82 1  شماره 

صفحات  -

تاریخ انتشار 2010