A Comparative Analysis of Several Corrected Vectorcardiographic Leads.

نویسندگان

  • D A BRODY
  • R C ARZBAECHER
چکیده

DURING the past decade a great deal of attention has been devoted to the development and application of one or more vectorcardiographic lead systems possessing certain highly desirable physical characteristics. The overriding design consideration has been that the lead system provide a truly Cartesian frame of reference for the display of cardiac vectors. Achievement of this goal requires that the axes of the three component leads be mutually orthogonal, that their individual electrocardiographic sensing abilities be equally scaled, and that both of the preceding properties remain essentially invariant throughout the cardiac region. Sets of electrocardiographic connections that attempt to satisfy these basic requirements are frequently referred to as corrected lead systems. They appear to be gaining increasing acceptance in vectorcardiographic practice. The ultimate test of a vectorcardiographic system lies in the demonstration of its reliability as a clinical diagnostic tool. Pending such clinical testing and confirmation, however, the special merits of corrected lead systems are predicated on their adherence to the specific design principles referred to above. Therefore it is of interest to examine the physical properties of such leads in detail and to determine how closely their parameters approximate the ideal situation. There is nothing basically new in the idea of exploring the physical properties of lead connections. Indeed, it was in this way that the

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Analysis of Several Corrected Vectoreardiographic Leads

DURING the past decade a great deal of attention has been devoted to the development and application of one or more vectorcardiographic lead systems possessing certain highly desirable physical characteristics. The overriding design consideration has been that the lead system provide a truly Cartesian frame of reference for the display of cardiac vectors. Achievement of this goal requires that ...

متن کامل

Intrinsic properties of uncorrected and highly corrected leads.

IT has become increasingly evident during the past several years that the single, fixedlocation dipole generator serves only as a firstorder approximation in accounting for the distribution of electrocardiographic potentials over the body surface.' 3 In principle any desired degree of approximation may be achieved by superimposing multipolar equivalent generators of higher order upon the dipole...

متن کامل

The Corrected Orthogonal Electrocardiogram and Vectorcardiogram in 510 Normal Men (frank Lead System).

A NUMBER of reports on normal ranges of corrected orthogonal electrocardiographic measurements have appeared in the literature.'-12 They were derived, however, from limited numbers of subjects and the types of electrocardiographic and vectorcardiographic measurements varied largely from one study to another. The reported results are therefore not always strictly comparable. In spite of these li...

متن کامل

The Corrected Orthogonal Electrocardiogram and Vectorcardiogram in 510 Normal Men ( Frank Lead System ) By HAROLD

A NUMBER of reports on normal ranges of corrected orthogonal electrocardiographic measurements have appeared in the literature.'-12 They were derived, however, from limited numbers of subjects and the types of electrocardiographic and vectorcardiographic measurements varied largely from one study to another. The reported results are therefore not always strictly comparable. In spite of these li...

متن کامل

The Corrected Orthogonal Electrocardiogram

A NUMBER of reports on normal ranges of corrected orthogonal electrocardiographic measurements have appeared in the literature.'-12 They were derived, however, from limited numbers of subjects and the types of electrocardiographic and vectorcardiographic measurements varied largely from one study to another. The reported results are therefore not always strictly comparable. In spite of these li...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 29  شماره 

صفحات  -

تاریخ انتشار 1964