Radiopharmaceuticals for nuclear cardiology: radiation dosimetry, uncertainties, and risk.

نویسنده

  • Michael G Stabin
چکیده

UNLABELLED The technical basis for the dose estimates for several radiopharmaceuticals used in nuclear cardiology is reviewed, and cases in which uncertainty has been encountered in the dosimetry of an agent are discussed. Also discussed is the issue of uncertainties in radiation dose estimates and how to compare the relative risks of studies. METHODS Radiation dose estimates (organ absorbed doses and effective doses) from different literature sources were directly compared. Typical values for administered activity per study were used to compare doses that are to be expected in clinical applications. RESULTS The effective doses for all agents varied from 2 to 15 mSv per study, with the lowest values being seen for (13)N-NH(3) and (15)O-H(2)O studies and the highest values being seen for (201)Tl-chloride studies. The effective doses for (99m)Tc- and (201)Tl-labeled agents differed by about a factor of 2, a factor that is comparable to the uncertainty in individual values. This uncertainty results from the application of standard anthropomorphic and biokinetic models, presumably representative of the exposed population, to individual patients. CONCLUSION Considerations such as diagnostic accuracy, ease of use, image quality, and patient comfort and convenience should generally dictate the choice of a radiopharmaceutical, with radiation dose being only a secondary or even tertiary consideration. Counseling of nuclear medicine patients who may be concerned about exposure should include a reasonable estimate of the median dose for the type of examination and administered activity of the radiopharmaceutical; in addition, it should be explained that the theoretic risks of the procedure are orders of magnitude lower than the actual benefits of the examination. Providing numeric estimates of risks from studies to individual patients is inappropriate, given the uncertainties in the dose estimates and the limited predictive power of current dose-risk models in the low-dose (i.e., diagnostic) range.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Minimizing and communicating radiation risk in pediatric nuclear medicine.

The value of pediatric nuclear medicine is well established. Pediatric patients are referred to nuclear medicine from nearly all pediatric specialties including urology, oncology, cardiology, gastroenterology, and orthopedics. Radiation exposure is associated with a potential, small, risk of inducing cancer in the patient later in life and is higher in younger patients. Recently, there has been...

متن کامل

Hybrid Phantom Applications to Nuclear Medicine

Annually, many people are irradiated for diagnostic and therapeutic purposes. Assessment of radiation dose and its related risks to patients are important issues in radiation protection dosimetry. The complex mathematical calculations of the absorbed and effective doses are now done with computers. The calculations are performed with the help of anthropomorphic computational models of human bod...

متن کامل

Internal Radiation Dose and Modeling Codes in Nuclear Medicine: A Fresh Look at Old Problems

With these codes, basic dose calculations could be made in seconds instead of hours. Another purpose of these codes was to help standardize dose calculations using recognized models, phantoms, and dosimetry techniques. In nuclear medicine community, the aim is to perform calculations to obtain dose estimates for various organs of the body once the kinetics of a radiopharmaceutical agent is esta...

متن کامل

Patient exposure to ionising radiation due to nuclear medicine cardiac procedures.

Nuclear cardiology procedures are among the most extensively performed radionuclide studies. Procedures for the assessment of myocardial perfusion, contractile function and metabolism have gained a prominent position in clinical practice. Health risk to patients from radiopharmaceuticals results only from exposure to ionizing radiation. Nuclear medicine diagnostic procedures,including the cardi...

متن کامل

Patient dose calculation software in nuclear medicine [Persian]

  Introduction: Radioactive materials deliver internal radiation dose to patients in nuclear medicine. Manual internal radiation dose assessment is a complicated method. Introduction of a simple dose calculation software is the main goal of the present study. Methods: Using the best current data in internal dose calculation (S-Factors) recommended by ICRP and by cons...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 49 9  شماره 

صفحات  -

تاریخ انتشار 2008