Clinical use of 11C-methionine and 18F-FDG-PET for germinoma in central nervous system
نویسندگان
چکیده
OBJECTIVE The purpose of this study was to examine the (11)C-methionine (MET) and (18)F-fluorodeoxyglucose (FDG) positron emission tomography (PET) findings of central nervous system (CNS) germinoma and the diagnostic utility of these findings. METHODS We retrospectively evaluated the cases of 10 patients who were diagnosed with CNS germinoma according to their histopathological or clinical findings. All the patients underwent pretreatment MET and/or FDG-PET scans, and the resultant images were assessed qualitatively and quantitatively. In the qualitative assessments, we used 3- and 5-grade visual scoring systems for the MET- and FDG-PET images, respectively. In the quantitative assessments, the maximal standardized uptake value (SUVmax) and the ratio of the SUVmax of the tumor (T) divided by the mean SUV for the normal white or gray matter [T/N (WM), T/N (GM)], was calculated. RESULTS The mean and SD values of SUVmax, T/N (WM), and T/N (GM) were 1.9 ± 1.4, 2.5 ± 1.3, and 1.7 ± 0.9 on MET-PET and 5.8 ± 2.2, 1.6 ± 0.5, and 0.8 ± 0.2 on FDG-PET, respectively. On MET-PET, only one lesion was not detected. On the other hand, on FDG-PET all of the lesions exhibited uptake values that were intermediate between those of the normal white matter and gray matter. CONCLUSION In terms of its tumor-contouring ability, MET is a good tracer for diagnosing CNS germinomas; therefore, MET-PET is considered to be useful for planning biopsies or surgery. Although FDG-PET is capable of detecting CNS germinomas, it produced insufficient image contrast in the present study. Further studies are needed before FDG-PET can be used in clinical examinations of CNS germinoma.
منابع مشابه
Diagnosis of Brain Tumors Using Amino Acid Transport PET Imaging With 18F- Fluciclovine: A Comparison Study With L-Methyl-11C-Methionine PET Imaging
Objective(s): 18F-fluciclovine (trans-1-amino-3-[18F] fluorocyclobutanecarboxylic acid, [FACBC]) is an artificial amino acid radiotracer used for positron emission tomography (PET) studies, which is metabolically stable in vivo and has a long half-life. It has already been shown that FACBC-PET is useful for glioma imaging. However, there have been no reports evaluating the efficiency of FACBC-P...
متن کاملC-11 Choline and FDG PET/CT Imaging of Primary Cholangiocarcinoma – a Comparative Analysis
Objective(s): This study aimed to compare the diagnostic values of 11C-choline and 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) in patients with cholangiocarcinoma (CCA). Methods: This prospective study was conducted on 10 patients (6 males and 4 females), aged 42-69 years, suspected of having CCA based on CT or magnetic resonance imaging (MRI) resu...
متن کاملKinetic Modelling of Infection Tracers [18F]FDG, [68Ga]Ga-Citrate, [11C]Methionine, and [11C]Donepezil in a Porcine Osteomyelitis Model
Introduction Positron emission tomography (PET) is increasingly applied for infection imaging using [18F]FDG as tracer, but uptake is unspecific. The present study compares the kinetics of [18F]FDG and three other PET tracers with relevance for infection imaging. Methods A juvenile porcine osteomyelitis model was used. Eleven pigs underwent PET/CT with 60-minute dynamic PET imaging of [18F]FD...
متن کاملDiagnostic Performance of Positron Emission Tomography for the Presurgical Evaluation of Patients with Non-lesional Intractable Partial Epilepsy: Comparison among 18F-FDG, 11C-Flumazenil, and 11C-Flumazenil Binding Potential Imaging Using Statistical Imaging Analysis.
To compare the diagnostic performance of 18F-FDG PET, 11C-FMZ PET, and 11C-FMZ BP imaging for the evaluation of patients with intractable partial epilepsy whose MRI findings are normal by using statistical imaging analysis. Ten patients underwent comprehensive presurgical evaluation, including PET studies, to assess the epileptic foci. The extent of cortical resection was based on the results o...
متن کاملFollicular thyroid cancer avid on C-11 Methionine PET/CT
A case of follicular thyroid cancer with intense focal Methionine uptake on 11C-Methionine PET/CT is reported here. The use of 11C-Methionine PET in differentiated thyroid cancer is currently being investigated as a surrogate tracer compared to the more widely used 18F-FDG PET. This case illustrates the potential incremental value of this modality, not only in the localizing of parathyroid aden...
متن کامل