Detection of Norovirus genogroup I and II by multiplex real-time RT- PCR using a 3'-minor groove binder-DNA probe

نویسندگان

  • Marina Hoehne
  • Eckart Schreier
چکیده

BACKGROUND Due to an increasing number of norovirus infections in the last years rapid, specific, and sensitive diagnostic tools are needed. Reverse transcriptase-polymerase chain reactions (RT-PCR) have become the methods of choice. To minimize the working time and the risk of carryover contamination during the multi-step procedure of PCR the multiplex real-time RT-PCR for the simultaneous detection of genogroup I (GI) and II (GII) offers advantages for the handling of large amounts of clinical specimens. METHODS We have developed and evaluated a multiplex one-tube RT-PCR using a combination of optimized GI and GII specific primers located in the junction between ORF1 and ORF2 of the norovirus genome. For the detection of GI samples, a 3'-minor groove binder-DNA probe (GI-MGB-probe) were designed and used for the multiplex real-time PCR. RESULTS Comparable results to those of our in-house nested PCR and monoplex real-time-PCR were only obtained using the GI specific MGB-probe. The MGB-probe forms extremely stable duplexes with single-stranded DNA targets, which enabled us to design a shorter probe (length 15 nucleotides) hybridizing to a more conserved part of the GI sequences. 97% of 100 previously norovirus positive specimens (tested by nested PCR and/or monoplex real-time PCR) were detected by the multiplex real-time PCR. A broad dynamic range from 2 x 10(1) to 2 x 10(7) genomic equivalents per assay using plasmid DNA standards for GI and GII were obtained and viral loads between 2.5 x 10(2) and 2 x 10(12) copies per ml stool suspension were detected. CONCLUSION The one-tube multiplex RT real-time PCR using a minor groove binder-DNA probe for GI is a fast, specific, sensitive and cost-effective tool for the detection of norovirus infections in both mass outbreaks and sporadic cases and may have also applications in food and environmental testing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of apple chlorotic leaf spot virus using a 5' nuclease assay with a fluorescent 3' minor groove binder-DNA probe.

The development of a real-time 5' nuclease RT-PCR assay for the detection of apple chlorotic leaf spot virus (ACLSV) from infected plant material is described. A short fluorogenic 3' minor groove binder-DNA hydrolysis probe was used to circumvent genome variability between isolates and target a short conserved sequence. The covalent attachment of the minor groove binder moiety at the 3' end of ...

متن کامل

Environmental detection of genogroup I, II, and IV noroviruses by using a generic real-time reverse transcription-PCR assay.

Norovirus is the most common agent implicated in food-borne outbreaks and is frequently detected in environmental samples. These viruses are highly diverse, and three genogroups (genogroup I [GI], GII, and GIV) infect humans. Being noncultivable viruses, real-time reverse transcription-PCR (RT-PCR) is the only sensitive method available for their detection in food or environmental samples. Sele...

متن کامل

Genogroup I and II noroviruses detected in stool samples by real-time reverse transcription-PCR using highly degenerate universal primers.

Genogroup I noroviruses from five genetic clusters and genogroup II noroviruses from eight genetic clusters were detected in stool extracts using degenerate primers and single-tube, real-time reverse transcription-PCR (RT-PCR) with SYBR Green detection. Two degenerate primer sets, designated MON 431-433 and MON 432-434, were designed from consensus sequences from the major clusters of norovirus...

متن کامل

Enhanced reverse transcription-PCR assay for detection of norovirus genogroup I.

We have developed a one-tube reverse transcription (RT)-PCR method using the real-time TaqMan PCR system for the detection of norovirus genogroup I (NV GGI). By introduction of a novel probe based on locked nucleic acid technology, we enhanced the sensitivity of the assay compared to those of conventional TaqMan probes. The sensitivity of the NV GGI RT-PCR was determined by probit analysis with...

متن کامل

Evaluation and validation of real-time reverse transcription-pcr assay using the LightCycler system for detection and quantitation of norovirus.

We developed an assay for the detection and quantitation of norovirus with the LightCycler SYBR Green-based real-time reverse transcription-PCR (real-time LC RT-PCR) and previously published primers in the capsid and the polymerase gene. One hundred thirty-two stool specimens from the Provincial Laboratory for Public Health (Microbiology), Alberta, Canada, and the Centers for Disease Control an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Infectious Diseases

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2006