Intraoperative fluorescence imaging system for on-site assessment of off-pump coronary artery bypass graft.

نویسندگان

  • Katsuhisa Waseda
  • Junya Ako
  • Takao Hasegawa
  • Yoshihisa Shimada
  • Fumiaki Ikeno
  • Toshihiro Ishikawa
  • Yoshitaka Demura
  • Kazuyoshi Hatada
  • Paul G Yock
  • Yasuhiro Honda
  • Peter J Fitzgerald
  • Masao Takahashi
چکیده

OBJECTIVES The aim of this study was to evaluate the intraoperative fluorescence imaging (IFI) system in the real-time assessment of graft patency during off-pump coronary artery bypass graft. BACKGROUND Intraoperative fluorescence imaging is an intraoperative angiography-like imaging modality using fluorescent indocyanine green excited with laser light. Recently, assessment of graft patency using the IFI system was introduced into clinical use. The feasibility and efficacy of IFI technology in off-pump coronary artery bypass graft has not been systematically compared with other conventional diagnostic modalities. METHODS Patients undergoing off-pump coronary artery bypass graft received IFI analysis, intraoperative transit time flowmetry, and postoperative X-ray angiography. In off-line IFI analysis, the graft washout was classified based on the number of heartbeats required for indocyanine green washout: fast washout (15 beats). RESULTS A total of 507 grafts in 137 patients received IFI analysis. Of all the IFI analyses, 379 (75%) grafts were visualized clearly up to the distal anastomosis. With regard to anastomosis location, anterior location was associated with a higher percentage of fully analyzable images (90%). More than 80% of images were analyzable, irrespective of graft type. Six grafts with acceptable transit time flowmetry results were diagnosed with graft failure by IFI, which required on-site graft revision. All revised grafts' patency was confirmed by post-operative X-ray angiography. Conversely, 21 grafts with unsatisfactory transit time flowmetry results demonstrated acceptable patency with IFI. Graft revision was considered unnecessary in these grafts, and 20 grafts (95%) were patent by post-operative X-ray angiography. Compared with slow washout, fast washout was associated with a higher preoperative ejection fraction, use of internal mammary artery grafts, and anterior anastomosis location. CONCLUSIONS The IFI system enables on-site assessment of graft patency, providing both morphologic and functional information. This technique may help reduce procedure-related, early graft failures in off-pump bypass patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

How I do it: high-quality intraoperative fluorescence imaging in off-pump coronary artery bypass grafting.

We have developed a simple technique for establishing high-quality intraoperative fluorescence imaging in off-pump coronary artery bypass grafting. The technique of transaortic injection of indocyanine green is an effective method of achieving clear fluorescence imaging and for evaluating the quality of graft anastomoses. We consider the images obtained with this technique to be equivalent to t...

متن کامل

Off-Pump Versus On-Pump Coronary Artery Bypass Graft Surgery, prospective cohort study

Introduction: Coronary artery bypass grafting is a surgical operation that bypasses atherosclerotic coronary vessels and restores blood flow to the ischemic zone of hearts. And two different conventional methods are ON-pump CABG, and Off-pump CABG.  Altogether, the efficacy and safety of these two types of surgical procedures are still under debate. In this study, we aim to com...

متن کامل

Comparison of Unstable Hemodynamic Patients Undergoing Coronary Artery Bypass Graft Surgery with on- or off-Pump Methods

Introduction: Coronary artery disease (CAD) is the most common type of heart disease, with a mortality rate of 385,000 person per year in the United States. There are two main methods for CAD treatments: angioplasty and bypass surgery. Coronary Artery Bypass Grafting (CABG) is one of the greatest surgical operations of the 20th century and it is presented as most effective and long-term therapi...

متن کامل

Evaluation of Factors Influencing Liver Function Test in On-Pump Coronary Artery Bypass Graft Surgery

Background: Liver dysfunction during on-pump coronary artery bypass graft surgery (CABG) is a rare complication but is associated with significant morbidity and mortality. The ability to identify high-risk patients may be helpful in planning appropriate management strategies. We aimed to evaluate the factors influencing liver function tests during on-pump CABG.Methods: In 146 patients scheduled...

متن کامل

Emergency Conversion from Off Pump to Cardiopulmonary Bypass in Patients with Coronary Artery Bypass Graft Surgery

Introduction: As off pump Coronary artery bypass grafting surgery (CABG) is a developing method in coronary cardiac surgery, most surgeons are anxious about the danger of emergency crash conversion. In this observational study we tried to show the rate and outcome of conversion . Material and methods: In this descriptive study about 477 coronary off-pump CABG patients were operated in Ghaem hos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular imaging

دوره 2 5  شماره 

صفحات  -

تاریخ انتشار 2009