Veneer fracture in implant-supported metal-ceramic restorations. Part I: Overall success rate and impact of occlusal guidance.
نویسندگان
چکیده
PURPOSE The aims of the presented study were to define the fracture rate of implant-supported metal-ceramic restorations delivered in private practice, and to identify if a restoration's contact during eccentric mandible movements has any influence on ceramic fracture rates. MATERIAL AND METHODS Within the period from 2005 to 2008, 251 patients, namely 105 men (42%) and 146 women (58%), received 775 dental implants which later were restored with metal-ceramic restorations. Data was gathered and analyzed in the form of a specially-designed electronic questionnaire. In total, 251 patients were rehabilitated with 350 prostheses consisting of 151 single crowns, 208 fixed partial dentures of various extents and 21 full-arch restorations. The method for retention of prostheses included cement-, screw-, or hybrid cement-screw retained prosthetic devices. The patients were recalled and examined for the presence of mechanical complications, namely ceramic fractures. Fractures were distinguished as adhesive or co-adhesive. The follow-up time was registered. RESULTS The mean ceramic fracture rate was 6.7%, as fracture occurred in 24 restorations. In the single crown group, the fracture rate was 1.3%, in the fixed partial denture division it was 6.7%, and the full-arch metal-ceramic restorations experienced 38.1% chipping. The mean follow-up period of prostheses was 9.5 months, ranging from 1 to 42 months. The analysis revealed that 66 prostheses had contact in protrusive and/or lateral mandibular movements, constituting 17.4% of all restorations; while 13 restorations had ceramic fractures, composing 19.7% of all guiding prostheses. CONCLUSIONS Within the limitations of this trial, it can be noted that ceramic veneer fracture rate was 6.7% in 380 restorations, and a conclusion that a restoration's contact during eccentric excursions may significantly enlarge fracture rates can be made.
منابع مشابه
Retrospective analysis of porcelain failures of metal ceramic crowns and fixed partial dentures supported by 729 implants in 152 patients: patient-specific and implant-specific predictors of ceramic failure.
STATEMENT OF PROBLEM Porcelain fracture associated with an implant-supported, metal ceramic crown or fixed partial denture occurs at a higher rate than in tooth-supported restorations, according to the literature. Implant-specific and patient-specific causes of ceramic failure have not been fully evaluated. PURPOSE The purpose of this retrospective study was to evaluate the potential statisti...
متن کاملInfluence of preparation design and ceramic thicknesses on fracture resistance and failure modes of premolar partial coverage restorations.
STATEMENT OF PROBLEM Preparation designs and ceramic thicknesses are key factors for the long-term success of minimally invasive premolar partial coverage restorations. However, only limited information is presently available on this topic. PURPOSE The purpose of this in vitro study was to evaluate the fracture resistance and failure modes of ceramic premolar partial coverage restorations wit...
متن کاملPorcelain fracture of metal-ceramic tooth-supported and implant-supported restorations: A review
Metal-ceramic restorations are widely used in dentistry with a high degree of general success. However, fracture of these restorations does occur and usually frustrates both the dentist and the patient. Objective: This literature review discusses the factors that may lead to the fracture of these restorations whether they are tooth-supported or implant-supported with the aim of making dentists ...
متن کاملA Comparative Evaluation of Shear Bond Strength of Creation Ceramic Veneer to Metal and Zirconia Cores
Abstract Background and Aim: High chipping rates of the veneering porcelain of zirconia ceramic restorations have been reported in clinical studies. Thus, the shear bond strength (SBS) between the zirconia core and veneering porcelain requires investigation. Materials and Methods: In this in-vitro study, at first, using a computer-aided design/computer-aided manufacturing (CAD/CAM) machine, 1...
متن کاملOutcome of bonded vs all-ceramic and metal- ceramic fixed prostheses for single tooth replacement.
AIM The conventional treatment of a single missing tooth is most frequently based on the provision of a fixed dental prosthesis (FDPs). A variety of designs and restorative materials are available which have an impact on the treatment outcome. Consequently, it was the aim of this review to compare resin-bonded, all-ceramic and metal-ceramic FDPs based on existing evidence. MATERIALS AND METHO...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stomatologija
دوره 10 4 شماره
صفحات -
تاریخ انتشار 2008