Optical extinction efficiency measurements on fine and accumulation mode aerosol using single particle cavity ring-down spectroscopy.

نویسندگان

  • Michael I Cotterell
  • Bernard J Mason
  • Thomas C Preston
  • Andrew J Orr-Ewing
  • Jonathan P Reid
چکیده

A new experiment is presented for the measurement of single aerosol particle extinction efficiencies, Qext, combining cavity ring-down spectroscopy (CRDS, λ = 405 nm) with a Bessel beam trap (λ = 532 nm) in tandem with phase function (PF) measurements. This approach allows direct measurements of the changing optical cross sections of individual aerosol particles over indefinite time-frames facilitating some of the most comprehensive measurements of the optical properties of aerosol particles so far made. Using volatile 1,2,6-hexanetriol droplets, Qext is measured over a continuous radius range with the measured Qext envelope well described by fitted cavity standing wave (CSW) Mie simulations. These fits allow the refractive index at 405 nm to be determined. Measurements are also presented of Qext variation with RH for two hygroscopic aqueous inorganic systems ((NH4)2SO4 and NaNO3). For the PF and the CSW Mie simulations, the refractive index, nλ, is parameterised in terms of the particle radius. The radius and refractive index at 532 nm are determined from PFs, while the refractive index at 405 nm is determined by comparison of the measured Qext to CSW Mie simulations. The refractive indices determined at the shorter wavelength are larger than at the longer wavelength consistent with the expected dispersion behaviour. The measured values at 405 nm are compared to estimates from volume mixing and molar refraction mixing rules, with the latter giving superior agreement. In addition, the first single-particle Qext measurements for accumulation mode aerosol are presented for droplets with radii as small as ∼300 nm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A portable pulsed cavity ring-down transmissometer for measurement of the optical extinction of the atmospheric aerosol.

A small portable system is described which is used to directly determine the optical extinction of the atmospheric aerosol. The requisite highly sensitive measurement of the optical extinction is accomplished simultaneously at two wavelengths in the near-infrared (1064 nm) and visible (532 nm), using the pulsed cavity ring-down (CRD) approach. The measurement at the two wavelengths can aid in s...

متن کامل

Measurements of Light Extinction by Single Aerosol Particles.

A Bessel beam optical trap is combined with continuous wave cavity ringdown spectroscopy to measure the extinction cross section of individual aerosol particles. Particles, ∼1 μm in size, can be captured indefinitely and processes that transform size or refractive index studied. The measured light extinction induced by the particle is shown to depend on the position of the particle in the cavit...

متن کامل

Interactive comment on “A Complete Parameterization of the Relative Humidity and Wavelength Dependence of the Refractive Index of Hygroscopic Inorganic Aerosol Particles” by Cotterell et al

Calculations of aerosol radiative forcing require knowledge of wavelength-dependent aerosol optical properties, 10 such as single scattering albedo. These aerosol optical properties can be calculated using Mie theory from knowledge of the key microphysical properties of particle size and refractive index, assuming that atmospheric particles are well-approximated to be spherical and homogeneous....

متن کامل

Deviations from plane-wave Mie scattering and precise retrieval of refractive index for a single spherical particle in an optical cavity.

The extinction cross-sections of individual, optically confined aerosol particles with radii of a micrometer or less can, in principle, be measured using cavity ring-down spectroscopy (CRDS). However, when the particle radius is comparable in magnitude to the wavelength of light stored in a high-finesse cavity, the phenomenological cross-section retrieved from a CRDS experiment depends on the l...

متن کامل

Aerosol Optical Extinction Measurements Using a Pulsed Laser

A recently developed portable instrument, the pulsed cavity ring-down transmissometer/nephelometer tandem (CRDT/N) allows for the in situ measurement of optical properties of aerosols. An Nd:YAG laser excited CRDT (λ = 532, 1064 nm) is shown to be capable of sensitively measuring the aerosol extinction coefficient (bext) at the two wavelengths simultaneously. Adding a nephelometer yields a meas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical chemistry chemical physics : PCCP

دوره 17 24  شماره 

صفحات  -

تاریخ انتشار 2015