Automated flow cytometric analysis of cerebrospinal fluid.

نویسندگان

  • J T Van Acker
  • J R Delanghe
  • M R Langlois
  • Y E Taes
  • M L De Buyzere
  • A G Verstraete
چکیده

BACKGROUND Recently, the UF-100 (Sysmex Corporation) flow cytometer was developed to automate urinalysis. We evaluated the use of flow cytometry in the analysis of cerebrospinal fluid (CSF). METHODS UF-100 data were correlated with microscopy and biochemical data for 256 CSF samples. Microbiological analysis was performed in 144 suspected cases of meningitis. RESULTS Good agreement was obtained between UF-100 and microscopy data for erythrocytes (r = 0.919) and leukocytes (r = 0.886). In some cases, however, incorrect classification of lymphocytes by the UF-100 led to underestimation of the leukocyte count. UF-100 bacterial count positively correlated (P < 0.001) with UF-100 leukocyte count (r = 0.666), CSF total protein (r = 0.754), and CSF lactate concentrations (r = 0.641), and negatively correlated with CSF glucose concentration (r = -0.405; P < 0.001). UF-100 bacterial counts were unreliable in hemorrhagic samples and in samples collected by ventricular drainage where interference by blood platelets and cell debris was observed. Another major problem was the UF-100 "bacterial" background signal in sterile CSF samples. Cryptococcus neoformans yeast cells and cholesterol crystals in craniopharyngioma were detected by the flow cytometer. CONCLUSIONS Flow cytometry of CSF with the UF-100 offers a rapid and reliable leukocytes and erythrocyte count. Additional settings offered by the instrument may be useful in the diagnosis of neurological disorders.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flow Cytometry of Nonhematopoietic Neoplasms

Many epithelial neoplasms can be analyzed by flow cytometry (FC), particularly from serous cavity effusion samples, using EpCAM, a cell adhesion molecule expressed on most normal epithelial cells and expressed at a higher level in most epithelial neoplasms. A simple 3-color flow cytometric panel can provide a high sensitivity and specificity compared to cytomorphology. FC provides more rapid im...

متن کامل

Flow Cytometry of Nonhematopoietic Neoplasms.

Many epithelial neoplasms can be analyzed by flow cytometry (FC), particularly from serous cavity effusion samples, using EpCAM, a cell adhesion molecule expressed on most normal epithelial cells and expressed at a higher level in most epithelial neoplasms. A simple 3-color flow cytometric panel can provide a high sensitivity and specificity compared to cytomorphology. FC provides more rapid im...

متن کامل

Flow cytometric analysis of cerebrospinal fluid has low diagnostic yield in samples without atypical morphology or prior history of hematologic malignancy.

OBJECTIVES To identify pretest characteristics of cerebrospinal fluid (CSF) specimens that will allow the rational use of flow cytometric analysis (FCA) in the diagnosis of hematologic malignancy. METHODS Retrospective data were collected on 501 consecutive CSF samples submitted for FCA. RESULTS A positive diagnosis of hematologic malignancy was made in 41 specimens (8.2%). Blasts or atypic...

متن کامل

Development of an RP-HPLC-UV method for simultaneous detection of nimodipine and its metabolite in cerebrospinal fluid of rat

A rapid, simple and reproducible HPLC method was developed and validated for the analysis of nimodipine (NM) and/or its metabolite, oxidized nimodipine (OX–NM) in rat cerebrospinal fluid (CSF) and artificial CSF. The NM and OX–NM were eluted in less than 10 min with no interferences from the endogenous CSF peaks. Analysis was carried out on a Eurospher Performance (RP-C18, 250 × 4.6 mm) column ...

متن کامل

Development of an RP-HPLC-UV method for simultaneous detection of nimodipine and its metabolite in cerebrospinal fluid of rat

A rapid, simple and reproducible HPLC method was developed and validated for the analysis of nimodipine (NM) and/or its metabolite, oxidized nimodipine (OX–NM) in rat cerebrospinal fluid (CSF) and artificial CSF. The NM and OX–NM were eluted in less than 10 min with no interferences from the endogenous CSF peaks. Analysis was carried out on a Eurospher Performance (RP-C18, 250 × 4.6 mm) column ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 47 3  شماره 

صفحات  -

تاریخ انتشار 2001