A Radiometric Study of Factors Affecting Drug Output of Jet Nebulizers

نویسندگان

  • G. Mittal
  • N. Kumar
  • H. Rawat
  • M. K. Chopra
  • A. Bhatnagar
چکیده

Jet nebulizers show an unreasonable variation in drug output and nebulization rates that leads to clinical and regulatory problems. Current evaluation methods appear inadequate for the purpose. Our objective was to evaluate Technetium-99m radiometry to study nebulizer parameters and the factors influencing it quantitatively. Drug output, output rate and residual mass and the effect of excipient, temperature, surface tension, air-jet speed, and equipment brand and aging were studied. Though nebulization of radiolabeled drugs followed first-order kinetics, the rates were significantly different; the heaviest drug (Tc-99m colloid) and Tc-99m salbutamol had the least nebulization. Nebulization rate for the first minute was invariably higher than the mean rate signifying the concentration effect of the solute. Drug residue was 35-75%. Drug output of different nebulizer chamber and air compressor brands was different to the extent of 270% and 180% respectively. 'Aging' of fluid chamber, cold drug fluid and obstruction in air-jet resulted in significant reduction in output, while addition of 2% saline as excipient did not change the output rate. Addition of ethyl alcohol resulted in a maximum of 260% enhancement (with Tc-99m salbutamol), while further reduction in surface tension was counterproductive irrespective of the drug used. We conclude that radiometry can provide valuable parametric information on the performance of different jet nebulizers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Drug output of unvented jet nebulizers as a function of time.

Nebulizer drug output rate increases during the nebulization. For unvented jet nebulizers, a physical and mathematical model based on the efficiency of the nebulization process is presented for this phenomenon. Formulas are derived for the cumulative drug output and the drug output rate of the nebulization process. The model is compared with the model proposed by Coates et al. [J. Aerosol. Med....

متن کامل

Comparison of drug delivery from conventional versus "Venturi" nebulizers.

Attempts to improve drug delivery from conventional jet nebulizers have included the use of storage systems to reduce drug wastage during exhalation. Venturi nebulizers enhance drug delivery during inhalation, reducing treatment times and drug wastage. This study investigated the effect of age on inhaled dose from a conventional jet nebulizer (Acorn) used both with and without a storage chamber...

متن کامل

A comparison of commercial jet nebulizers.

Seventeen commercially available jet nebulizers from 15 commercial sources were studied (Acorn-I, Acorn-II, AquaTower, AVA-NEB, Cirrhus, Dart, DeVilbiss 646, Downdraft, Fan Jet, MB-5, Misty Neb, PARI LC JET, PARI-JET, Salter 8900, Sidestream, Updraft-II, Whisper Jet). All nebulizers were filled with 2 ml of saline solution plus 0.5 ml of albuterol and powered with the same source (DeVilbiss Pul...

متن کامل

Effect of dead volume on the efficiency and the cost to deliver medications in cystic fibrosis with four disposable nebulizers.

OBJECTIVES To evaluate the factors that affect nebulizer efficiency and to compare the relative cost effectiveness of nebulized medications used in the treatment of cystic fibrosis (CF), delivered by four types of disposable jet nebulizers that are widely used in hospitals. DESIGN The Hudson 1730 Updraft II, Baxter Misty-Neb, Marquest Whisper Jet (WJ), and Marquest Acorn II were evaluated in ...

متن کامل

Droplets produced by medical nebulizers. Some factors affecting their size and solute concentration.

The effect of nebulizer solution temperature and dilution air humidity on the size and solute concentration of aqueous aerosol droplets were studied. Four combinations of jet-nebulizers with air compressors or oxygen sources and one ultrasonic nebulizer were tested. The temperature to which the nebulizer solution of each system fell during generation was measured. The nebulizers were then kept ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 72  شماره 

صفحات  -

تاریخ انتشار 2010