A customized fixation plate with novel structure designed by topological optimization for mandibular angle fracture based on finite element analysis
نویسندگان
چکیده
BACKGROUND The purpose of this study was to design a customized fixation plate for mandibular angle fracture using topological optimization based on the biomechanical properties of the two conventional fixation systems, and compare the results of stress, strain and displacement distributions calculated by finite element analysis (FEA). METHODS A three-dimensional (3D) virtual mandible was reconstructed from CT images with a mimic angle fracture and a 1 mm gap between two bone segments, and then a FEA model, including volume mesh with inhomogeneous bone material properties, three loading conditions and constraints (muscles and condyles), was created to design a customized plate using topological optimization method, then the shape of the plate was referenced from the stress concentrated area on an initial part created from thickened bone surface for optimal calculation, and then the plate was formulated as "V" pattern according to dimensions of standard mini-plate finally. To compare the biomechanical behavior of the "V" plate and other conventional mini-plates for angle fracture fixation, two conventional fixation systems were used: type A, one standard mini-plate, and type B, two standard mini-plates, and the stress, strain and displacement distributions within the three fixation systems were compared and discussed. RESULTS The stress, strain and displacement distributions to the angle fractured mandible with three different fixation modalities were collected, respectively, and the maximum stress for each model emerged at the mandibular ramus or screw holes. Under the same loading conditions, the maximum stress on the customized fixation system decreased 74.3, 75.6 and 70.6% compared to type A, and 34.9, 34.1, and 39.6% compared to type B. All maximum von Mises stresses of mandible were well below the allowable stress of human bone, as well as maximum principal strain. And the displacement diagram of bony segments indicated the effect of treatment with different fixation systems. CONCLUSIONS The customized fixation system with topological optimized structure has good biomechanical behavior for mandibular angle fracture because the stress, strain and displacement within the plate could be reduced significantly comparing to conventional "one mini-plate" or "two mini-plates" systems. The design methodology for customized fixation system could be used for other fractures in mandible or other bones to acquire better mechanical behavior of the system and improve stable environment for bone healing. And together with SLM, the customized plate with optimal structure could be designed and fabricated rapidly to satisfy the urgent time requirements for treatment.
منابع مشابه
Treatment of a Mandibular Fracture by Two Perpendicular Mini-Plates
Introduction: In open reduction and internal fixation for the treatment of mandibular fracture, the fixation technique used is very important in reducing post-operative complications and promoting the healing process. This study assessed the results of fixation of the mandible using two mini-plates perpendicular to each other in the lower border of the mandible for fracture treatment. Materi...
متن کاملDevelopment of a Titanium Plate for Mandibular Angle Fractures with a Bone Defect in the Lower Border: Finite Element Analysis and Mechanical Test
OBJECTIVES The aim of the present study was to develop a plate to treat mandibular angle fractures using the finite element method and mechanical testing. MATERIAL AND METHODS A three-dimensional model of a fractured mandible was generated using Rhinoceros 4.0 software. The models were exported to ANSYS(®), in which a static application of displacement (3 mm) was performed in the first molar ...
متن کاملPropagation of Crack in Linear Elastic Materials with Considering Crack Path Correction Factor
Modeling of crack propagation by a finite element method under mixed mode conditions is of prime importance in the fracture mechanics. This article describes an application of finite element method to the analysis of mixed mode crack growth in linear elastic fracture mechanics. Crack - growth process is simulated by an incremental crack-extension analysis based on the maximum principal stress c...
متن کاملBiomechanical evaluation of a novel dualplate fixation method for proximal humeral fractures without medial support
BACKGROUND Comminuted fractures of the proximal humerus are generally treated with the locking plate system, and clinical results are satisfactory. However, unstable support of the medial column results in varus malunion and screw perforation. We designed a novel medial anatomical locking plate (MLP) to directly support the medial column. Theoretically, the combined application of locking plate...
متن کاملLate treatment of a mandibular gunshot wound
Mandibular gunshot injuries are esthetically and functionally devastating, causing comminuted fractures and adjacent tissue destruction depending on the weapon gauge, projectile shape, impact kinetic energy, and density of the injured structures. If the mandibular fracture is not adequate or promptly treated, the broken fragments will fail to heal. In case of a treatment delay, progressive bone...
متن کامل