Electromagnetic and thermal modeling of SAR and temperature fields in tissue due to an RF decoupling coil.

نویسندگان

  • J W Hand
  • R W Lau
  • J J Lagendijk
  • J Ling
  • M Burl
  • I R Young
چکیده

The finite difference time domain method is used to calculate the specific absorption rate (SAR) due to a butterfly surface coil in a realistic tissue model of the leg. The resulting temperature distribution and temperature changes are found using a finite difference solution to the bioheat transfer equation. Reasonable agreement is found between predicted temperature changes and those measured in vivo provided that the resulting hyperthermia does not induce noticeable changes in perfusion. The method is applicable to radiofrequency dosimetry problems associated with high Bo field magnetic resonance systems and where knowledge of spatial variation in SAR is important in assessing the safety of new magnetic resonance procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SAR and tissue heating with a clinical (31)P MRS protocol using surface coils, adiabatic pulses, and proton-decoupling.

In MRS studies using surface transmit coils, accurate assessment of local SAR and RF heating represents a difficult problem involving the coil geometry and electromagnetic and geometric tissue properties. Methodologies to determine the optimum operating parameters for dual-resonant surface coil measurements are presented, based on a standardized coil and protocol used in a multicenter (31)P MRS...

متن کامل

MR safety assessment of potential RF heating from cranial fixation plates at 7 T.

PURPOSE The increasing number of clinically oriented MRI studies at 7 T motivates the safety assessment of implants, since many 7 T research sites conservatively exclude all subjects with metallic implants, regardless of type or location. The purpose of this study was to investigate potential RF-induced heating during a 7 T MRI scan using a self-built transmit/receive RF coil in patients with i...

متن کامل

Numerical Calculation on Electromagnetic Energy Absorption in Pregnant Woman by RF Coil for MRI System

The numerical calculations including voxel human model with an anatomical structure for electromagnetic field and temperature rise induced by electromagnetic energy absorption have been widely investigated over the past dozen years or so. This paper presents the computational electromagnetic dosimetry inside an anatomically based pregnant woman models exposed to electromagnetic wave during magn...

متن کامل

Survey of the Effects of Exposure to 900 MHz Radiofrequency Radiation Emitted by a GSM Mobile Phone on the Pattern of Muscle Contractions in an Animal Model

Introduction: The rapid development of wireless telecommunication technologies over the past decades, has led to significant changes in the exposure of the general public to electromagnetic fields. Nowadays, people are continuously exposed to different sources of electromagnetic fields such as mobile phones, mobile base stations, cordless phones, Wi-Fi routers, and power lines. Therefore, th...

متن کامل

Evaluation of RF Heating of a Multi-Mode Intravascular MRI Coil

Accurate and reliable guidance is crucial for catheter-based treatment of cardiac diseases such as atrial fibrillation. Magnetic resonance imaging (MRI) is a preferable choice because of good soft tissue contrast, 3D capability, and lack of ionizing radiation. Higher resolution imaging of the region of interest such as arteries and pulmonary vein is desirable. Intravascular MRI coils have been ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 42 1  شماره 

صفحات  -

تاریخ انتشار 1999