Functional immunoassay technology (FIT), a new approach for measuring physiological functions: application of FIT to measure glomerular filtration rate (GFR).

نویسندگان

  • Christopher Peter Reinhardt
  • Michael J Germain
  • Ernest V Groman
  • Jeffrey G Mulhern
  • Rajesh Kumar
  • Dennis E Vaccaro
چکیده

This is the first description of functional immunoassay technology (FIT), which as a diagnostic tool has broad application across the whole spectrum of physiological measurements. In this paper, FIT is used to measure the renal clearance of an ultra low-dose administration of a clinically available contrast reagent for the purpose of obtaining an accurate glomerular filtration rate (GFR) measurement. Biomarker-based GFR estimates offer convenience, but are not accurate and are often misleading. FIT overcomes previous analytic barriers associated with obtaining an accurate GFR measurement. We present the performance characteristics of this diagnostic test and demonstrate the method by directly comparing GFR values obtained by FIT to those obtained by an FDA approved nuclear test in 20 adults. Two subjects were healthy volunteers and the remaining 18 subjects had diagnosed chronic kidney disease, with 12 being kidney transplant recipients. Measured GFR values were calculated by the classic UV/P method and by the blood clearance method. GFR obtained by FIT and the nuclear test correlated closely over a wide range of GFR values (10.9-102.1 ml.min(-1).1.73 m(-2)). The study demonstrates that FIT-GFR provides an accurate and reproducible measurement. This nonradioactive, immunoassay-based approach offers many advantages, chiefly that most laboratories already have the equipment and trained personnel necessary to run an ELISA, and therefore this important diagnostic measurement can more readily be obtained. The FIT-GFR test can be used throughout the pharmaceutical development pipeline: preclinical and clinical trials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

How Measuring Glomerular Filtration Rate? Comparison of Reference Methods

Glomerular filtration rate (GFR) is considered as the best way to assess global renal function (Gaspari et al., 1997; Stevens & Levey, 2009). Even if GFR estimations (based on creatinineor cystatin C-based equations) are most often used (see Table 1)(Cockcroft & Gault, 1976; Levey et al., 1999; Levey et al., 2006; Levey et al., 2009), measuring “true” GFR is still important in clinical practice...

متن کامل

Glomerular Filtration Rate and Error Calculation Based on the Slope-Intercept Method with Chromium-51 Ethylenediaminetetraacetic Acid via a New Clinical Software: GFRcalc

OBJECTIVE To evaluate a home-built Java-based program (GFRcalc) to simplify the calculation of glomerular filtration rate (GFR) after administration of chromium-51 ethylenediaminetetraacetic acid (51Cr-EDTA) for routine clinical use. MATERIALS AND METHODS In the program GFRcalc, the GFR was calculated based on the biological half-life of the 51Cr-EDTA concentration using the slope-intercept m...

متن کامل

SERUM CYSTATIN C AS A NEW MARKER OF GLOMERULAR FILTRATION RATE (GFR)

Cystatin C is a 13 KD basic protein that is a member of the cystatin superfamily of cysteine protease inhibitors. The cystatin C gene seems to be a house keeping gene, which is compatible with a stable production rate of cystatin C by most cells. This protein is freely filtered through the glomerulus and almost completely reabsorbed and catabolized by proximal tubular cells. Because of the...

متن کامل

A simple method for measuring severely reduced glomerular filtration rate.

OBJECTIVE The purpose of this study was to develop a simpler method to measure severely reduced glomerular filtration rate (GFR) for patients with a GFR below 30 mL/min. METHOD The GFR was measured in 24 patients using both the 51Cr EDTA slope-intercept method (the conventional method) and 99mTc-DTPA with our proposed simpler GFRn method. RESULTS The correlation coefficient was 0.92 between...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Renal physiology

دوره 295 5  شماره 

صفحات  -

تاریخ انتشار 2008