Calculation of clothing insulation by serial and parallel methods: effects on clothing choice by IREQ and thermal responses in the cold.
نویسندگان
چکیده
Cold protective clothing was studied in 2 European Union projects. The objectives were (a) to examine different insulation calculation methods as measured on a manikin (serial or parallel), for the prediction of cold stress (IREQ); (b) to consider the effects of cold protective clothing on metabolic rate; (c) to evaluate the movement and wind correction of clothing insulation values. Tests were carried out on 8 subjects. The results showed the possibility of incorporating the effect of increases in metabolic rate values due to thick cold protective clothing into the IREQ model. Using the higher thermal insulation value from the serial method in the IREQ prediction, would lead to unacceptable cooling of the users. Thus, only the parallel insulation calculation method in EN 342:2004 should be used. The wind and motion correction equation (No. 2) gave realistic values for total resultant insulation; dynamic testing according to EN 342:2004 may be omitted.
منابع مشابه
Protection of Human in the Working Environment
Cold protective clothing was studied in 2 European Union projects. The objectives were (a) to examine different insulation calculation methods as measured on a manikin (serial or parallel), for the prediction of cold stress (IREQ); (b) to consider the effects of cold protective clothing on metabolic rate; (c) to evaluate the movement and wind correction of clothing insulation values. Tests were...
متن کاملPrediction of duration limited exposure for participants wearing chemical protective clothing in the cold.
The suitability of the IREQ (insulation required) index for predicting the thermal responses of 6 participants wearing chemical protective clothing was tested during exercise at -20 and -25 degrees C. IREQ was used to calculate duration limited exposure (DLE). Measured DLE correlated (r =0.899, p <0.001) with the predicted DLE. In exposures exceeding 40 min, however, the predicted DLE tended to...
متن کاملEvaluation of Occupational Cold Environments: Field Measurements and Subjective Analysis
The present work is dedicated to the study of occupational cold environments in food distribution industrial units. Field measurements and a subjective assessment based on an individual questionnaire were considered. The survey was carried out in 5 Portuguese companies. The field measurements include 26 workplaces, while a sample of 160 responses was considered for the subjective assessment. In...
متن کاملParallel and serial methods of calculating thermal insulation in European manikin standards.
Standard No. EN 15831:2004 provides 2 methods of calculating insulation: parallel and serial. The parallel method is similar to the global one defined in Standard No. ISO 9920:2007. Standards No. EN 342:2004, EN 14058:2004 and EN 13537:2002 refer to the methods defined in Standard No. EN ISO 15831:2004 for testing cold protective clothing or equipment. However, it is necessary to consider sever...
متن کاملThermal manikin measurements--exact or not?
According to the European prestandard ENV 342:1998, the thermal insulation of cold-protective clothing is measured with a thermal manikin. Systematic studies on the reproducibility of the values, measured with different types of clothing on the commonly used standing and walking manikins, have not been reported in the literature. Over 300 measurements were done in 8 different European laborator...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of occupational safety and ergonomics : JOSE
دوره 13 2 شماره
صفحات -
تاریخ انتشار 2007