Parallel Beam Powder Diffractometry Using a Laboratory X-Ray Source

نویسنده

  • R. D. Deslattes
چکیده

We report on the application of a new, non-dispersive double multilayer optical arrangement to prepare a parallel beam from a laboratory x-ray source for standardization of powder diffraction reference materials and the associated high accuracy diffractometer. The beam preparation optic uses a graded-spacing parabolic multilayer to gather radiation from a small focus x-ray source and a subsequent planar multilayer with spacing near the mean of the graded multilayer to redirect the radiation toward the powder specimen. Diffracted radiation, after analysis by a well-characterized Soller collimator, is registered in a proportional counter. The instrumental geometry permits wide range symmetrical scanning about the incident beam direction allowing elimination of errors associated with zero diffraction angle location. Initial performance metrics of the present diffractometer and the availability of accurate, optically-based profile parameters for the Cu Ka doublet connected to the base unit for length by x-ray (lattice) interferometry, assure that future standard reference powder samples will be certifiable to within parts per million. Background and motivation The vast majority of powder diffraction measurements use conventional laboratory x-ray sources (including rotating anodes) with parafocussing optics to accommodate the low signal levels intrinsic to powder samples. Unfortunately, achieving this gain in signal level entails concomitant sensitivities to sample positioning and beam penetration depth which exclude such measurements from first-principles accuracy. Instead, such measurements often rely on externally supplied powder diffraction standards used either sequentially or, more frequently, mixed with the subject specimen to provide ‘internal’ standardization. NIST, as the primary provider of the needed standard reference materials (SRM’s), currently faces a diminishing inventory whose accuracies are limited by the methods used in their certification [ 11. In this circumstance, we have undertaken to devise a robust procedure for first-principles standardization of the next generation of powder SRM’s with improved connection to the base unit for distance in the international system of units, the SI. It is particularly useful to take advantage of the progress made in the last 20 years in connecting the lattice spacings of certain highly perfect single crystals with optical realizations of length in the SI. Coovriaht 0 JCPDS-international Centre for Diffraction Data 1997 Copyright (C) JCPDS-International Centre for Diffraction Data 1997 Among the requirements for a first-principles (standards-free) measurement are the use of parallel beam optics, and registration of geometrically complementary patterns, i.e., scans taken both clockwise and counter-clockwise with respect to the incident beam direction, as well as accurate measurement of the angular displacements. The use of parallel beam geometry eliminates all sensitivity to the sample’s centration, and the penetration depth of the radiation. Similarly, symmetric scanning removes the need to invoke an auxiliary operation to locate the diffractometer’s zero point. The procedures we describe are straightforward and can be applied in other laboratories to reproduce our results or wherever standards-free measurements are needed. They are, however, designed for highly accurate studies of relatively simple patterns and are not well suited to rapid analysis or complex patterns. The advantages of parallel beam diffractometry are well known and have motivated the establishment of beamlines dedicated to powder diffraction measurements at synchrotron radiation facilities [2]. The instrumental configurations of these beamlines have been chosen to realize many of the advantages of parallel beam optics without, however, addressing the need to map mirror-symmetric reflections, or providing means to accurately establish the incident wavelength; both steps are required for first principles measurements. Beam preparation optics We examined a wide range of beam preparation optics, beginning with a strong inclination to the use of highly perfect monocrystals in quasi-non-dispersive arrangements. While these crystal-based options have many advantages, including ease of realization with silicon and germanium, the high spectral resolution inherent in crystal diffraction optics entails a potential imprecision in tuning to the peak of, let us say, Kal. In addition, while perfect crystal optics are very successfully used in beam preparation for powder diffraction with synchrotron radiation, when they are used with a laboratory source, data rates become very low. Large gains in flux have been realized in recent times by use of graded-spacing multilayers on parabolic substrates [3]. The use of such elements to feed crystal diffractors or monochromators (including Bartels configurations) has been discussed extensively [4]. Although we gave extended consideration to this approach, certain practical limitations recommended against it in our application. The first problem is that it shares, to some extent, the same difficulties as noted above for the case of a perfect crystal beam conditioner. The flux deficit is clearly reduced but nevertheless remains significant. The wavelength indeterminacy requires routine re-mapping of the profile to assure stability of the delivered wavelength. In the end we have developed a new approach to beam preparation for powder diffraction by combining a graded-spacing parabolic diffractor with a flat multilayer optic having a grating spacing equal to the mean value of the spacing of the graded multilayer [5]. We arrange these in a non-dispersive configuration as suggested in the diagram shown in Fig. 1. For reasons of efficiency, operation is at the first order Bragg reflection (near l”), Copyright (C) JCPDS-International Centre for Diffracti Data 1997 Parabolic mirror with Graded spacing Multilayer X-ray Flat multilayer mirror source fiigure 1. Beam forrnmg optic consisting of a graded-spacing parabolic multilayer followed by a planar multilayer with a d-spacing equal to the mean value of the collimating reflector. a value which results in very small wavelength dispersion from either multilayer, while the “minus” configuration effectively allows the two dispersions to nearly cancel. The effect of these choices is to provide a beam filtered by the diffractors but still including, with no perceptible distortion, both components of the Ka doublet; the effective passband is approximately 50 eV, which should be compared with the 20 eV separation of the doublet components and the much narrower linewidths of the individual components. The beam is nonetheless well collimated with an angular spread of approximately 0.01“. The small spectral dispersion should allow use of optically based, high accuracy doublet profiles, as will be discussed below, thereby eliminating wavelength setting imprecision. In addition, flux levels delivered to the powder sample, as shown below, are high enough for convenient measurement cycle times with a modest (2 kW) laboratory x-ray source. Finally, the very small dispersion means that profiles on both sides of zero angle have closely similar appearance for sufficiently large diffraction angles; they differ because the intrinsic powder dispersion is on one side proportional to (tan8 + tan 1”) while on the other side it is proportional to (tan8 tan 1”). Use of other anode materials requires retuning of the multilayer elements or interchange of other pre-aligned pairs. Diffractometer design The general disposition of our new diffractometer is indicated in Fig. 2 where we show the geometry for diffraction on both sides of the zero angle at 20 =+90”; the single detector and diffracted beam collimator are shown in the two positions appropriate for a Copyright (C) JCPDS-International Centre for Diffraction Data 1997 Bragg angle (0 ) of 45”; these are separated by 48. The input beam preparation optic is as described above. The exit Soller collimator and proportional counter detector are carried by a large (80 cm dia.) rotary platform driven by a stepping motor through relatively imprecise spur gearing. The platform’s rotation is, however, monitored by a high resolution optical incremental encoder with 12000 cycles per revolution and a 2-station readout whose calibration and performance are described below. The powder sample is mounted on a separate, worm-driven rotary stage which surmounts the Exit Soiler Collimator :; f Soiler Collimator (Axially limiting) Soller Collimator (Axially limiting) Figure 2. Functional layout of parallel beam powder diffractometer ( neither components nor distances are to scale). The sample, exit Soller collimator, and detector are shown in positions corresponding to a Bragg angle of 45”. main platform. By driving the sample stage at half the platform speed in the opposing direction, we maintain the conventional 6 28 configuration. Sample rotation about the diffraction vector is effected by a spinner motor whose drive passes through the encoder and both rotary stages; particle statistics can be further improved by rocking the sample through a few degrees during data accumulation. When using the reflection geometry shown, the scan must be interrupted at zero degrees to allow the sample to be rotated by 180” (so as to present the same sample surface to the beam) before proceeding into the other diffraction sector. Copyright (C) JCPDS-International Centre for Diffraction Data 1997 While the present report is not intended to provide a detailed description of the instrumentation and procedures, a few technical comments are in order. The overall system is under computer control and uses encoder-guided, software-implemented rotation control to overcome its mechanical limitations. Although the angle encoder in use at the present time had an established calibration history, we believe that routine in situ calibration of the angle scale is needed if one wants to obtain defensibly accurate measurement of diffraction angles; our procedure is based on the use of an interferometrically calibrated optical polygon to get a correction table for large angular displacements, and application of a rotating optical wedge to map local interpolation errors [6]. We expect the final angular calibration to provide for robust estimates of the measured (48 ) intervals at the 0.5 set level, thereby contributing insignificantly to the final error budget for Bragg angles around 40” and above. The high degree of beam collimation provided by the input multilayer doublet means that, aside from intrinsic broadening and axial divergence (limited to kO.75” by the axial collimator shown), the dominant resolution limiter is the exit Soller collimator. In our experience to date, this is a very significant problem, particularly since our goal is total profile fitting. To convey a sense of the problem, Fig. 3 shows angular transmission profiles for two of the collimators we have studied that indicate the currently significant limitation arising from this component. From the indicated transmission function measurements, it is clear that the higher resolution collimator has an unpleasantly complex transmission profile including high and asymmetric off-axis transparency; the indicated asymmetry reverses as expected when the collimator’s input and output directions are interchanged. Our most effective collimator is, in fact, the one having poorer angular resolution but, as can be seen in the upper part of Fig. 3 a rather symmetric profile with low transmission in the ‘tail’ region. While the contribution of total reflection to this profile is suggested by the shape, this level of detail has not been further explored in anticipation of planned technical improvements. We have chosen to use a xenon proportional counter for x-ray detection for several reasons: The first is to reduce sensitivity to higher order x-radiation and gain improved energy discrimination for background reduction. The second reason is simply mechanical in that our experimental configuration is intolerant of the additional extension along the diffracted beam direction required by a conventionally configured scintillation counter with its attached end-window photomultiplier.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Synthesis and characterization of Gd2O2 S: Tb3+ phosphor powder for X-ray imaging detectors

Gadolinium oxysulfide phosphor doped with trivalent terbium have been synthesized using urea homogenous precipitation and followed by sulfurization at 800 °C under argon atmosphere. Structural and morphological of synthesized phosphor powder were characterized by x-ray diffraction (XRD), scanning electron microscopy (SEM) and Fourier transform infrared spectrometry (FT-IR). Hexagonal structure ...

متن کامل

Estimation of purity of chrysotile asbestos by X-ray diffractometry/Rietveld refinement.

X-ray powder diffractometry/Rietveld refinement was employed to estimate the purity of several chrysotile powders for calibrating standards. α-Corundum powder was mixed into each chrysotile sample as an internal standard. X-ray diffractometry was performed on these mixtures, and the mass fractions of amorphous and impurity phase content were calculated using Rietveld refinement. The chrysotile ...

متن کامل

SYNTHESIS AND CHARACTERIZATION OFSILICON CARBIDE NANO POWDER BYSOLGELPROCESSING

Abstract: SiC nano particles with mono dispersed distribution were synthesized by using of silicon alkoxides and phenolic resin as starting materials. After synthesis of sample, characterizations of the obtained powder were investigated via Fourier Transform Infrared Spectroscopy (FTIR) with 400-4000 cm-1, X-ray Diffractometry (XRD), Laser Particle Size Analyzing (LPSA), Si29 NMR analysis, Scan...

متن کامل

X-ray diffractometry for the structure determination of a submicrometre single powder grain

A high-precision diffractometer has been developed for the structure analysis of a submicrometre-scale single grain of a powder sample at the SPring-8 BL40XU undulator beamline. The key design concept is the combination of a stable focused synchrotron radiation beam and the precise axis control of the diffractometer, which allows accurate diffraction intensity data of a submicrometre-scale sing...

متن کامل

Preparation and evaluation of a chrysotile asbestos-containing standard material for validating x-ray diffractometric quantitation.

A standard material containing chrysotile asbestos for the validation of x-ray diffractometric quantitation was developed using an asbestos-containing building material i.e., perlite board. The board as the base material was crushed, pulverized, and homogenized. The homogeneity of the powder of perlite board was estimated by analysis of variance. The diffraction intensity values of the crystall...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998