Effectiveness of resonance frequency in predicting orthopedic implant strength and stability in an in vitro osseointegration model.
نویسندگان
چکیده
Developing noninvasive tools that determine implant attachment strength to bone and monitor implant stability over time will be important to optimize rehabilitation protocols following insertion of osseointegrated implants in patients with limb loss. While resonance frequency has been previously shown to correlate with implant stability in dental implants placed in the mandible and maxilla, this tool has not been evaluated with implants placed in the medullary canal of long bones. In an in vitro model used to simulate irregular medullary canal implant contact and osseointegration, a strong positive correlation was determined between resonance frequency implant stability quotient values and the force required for implant pushout. The force required for implant displacement also correlated to the distance from the point of fixation to the transducer at the proximal end of the implant (point of resonance frequency monitoring).
منابع مشابه
The Influence of Site Preparation (Countersinking) on Initial Dental Implant Stability. An in vitro Study Using Resonance Frequency Analysis
Primary implant stability is considered to be a critical factor for obtaining successful osseointegration [1]. Studies using Resonance Frequency Analysis (RFA) have demonstrated that initial implant stability is determined by the density of the bone, the surgical technique used, and the design of the implant [2, 3]. While different implant designs have shown similar results of higher stabilitie...
متن کاملA noncontact detection technique for interfacial bone defects and osseointegration assessment surrounding dental implants
Dental implantation is popular treatment for edentulous and partially dentate patients. Effectively assessing interfacial bone defects and osseointegration requires considerable effort for successful implantation. This study presents the development of a noncontact detection technique that uses a loudspeaker and a noncontact cylindrical capacitive-type displacement sensor to measure and evaluat...
متن کاملClinical evaluation of osseointegration using resonance frequency analysis
The stability of the implant at the time of placement and during the development of the osseointegration process are the two major issues governing the implant survival. Implant stability is a mechanical phenomenon related to local factors such as bone quality, quantity, type of placement technique and type of implant used. The application of a user-friendly, clinically reliable, non-invasive m...
متن کاملResonance frequency analysis of implant stability in augmented and non-augmented sinus sites
Background and aim: Although there have been substantial developments in dental implant therapies, achieving good implant stability (ISQ >60) for implants inserted in augmented sinus sites appears to be challenging in comparison with non-augmented sites due to the high prevalence of bone resorption in posterior regions of maxilla. This study aimed to evaluate and compare the time required to a...
متن کاملThe influence of length of implant on primary stability: An in vitro study using resonance frequency analysis
BACKGROUND Primary stabilityis not sufficientin less contact area between the implant and bone, the healing process because will be disrupted due to micro-motions and fibrous tissue affects osseointegration. MATERIAL AND METHODS We implemented an in vitro experimental study of total 135 XiVE® implants were inserted in 22.5 bovine cow ribs with bone quality similar to a type IV human bone. Eac...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of rehabilitation research and development
دوره 46 9 شماره
صفحات -
تاریخ انتشار 2009