Evaluating the PAS-SIM model using a passive air sampler calibration study for pesticides.
نویسندگان
چکیده
The main objective of this study was to evaluate the performance of a model for simulating the uptake of various pesticides on passive air samplers (PAS). From 2006-2007 a series of PAS using XAD-resin were deployed at Egbert, a rural agricultural site in southern Ontario, Canada, to measure the uptake of pesticides for time periods ranging from two months to one year. A continuous increase in sequestered amounts was observed for most pesticides, except for trifluralin and pendimethalin, which could conceivably be subject to substantial degradation inside the sampler. Continuous low-volume active air samples taken during the same period, along with data on weather conditions, allowed for the simulation of the uptake of the pesticides using the model (PAS-SIM). The modelled accumulation of pesticides on the PAS over the deployment period was in good agreement with the experimental data in most cases (i.e., within a factor of two) providing insight into the uptake kinetics of this type of sampler in the field. Passive sampling rates (PSR, m(3) d(-1)) were determined from the empirical data generated for this study using three different methods and compared with the PSRs generated by the model. Overall, the PAS-SIM model, which is capable of accounting for the influence of temperature and wind variations on PSRs, provided reasonable results that range between the three empirical approaches employed and well-established literature values. Further evaluation and application of the PAS-SIM model to explore the potential spatial and temporal variability in PAS uptake kinetics is warranted, particularly for established monitoring sites where detailed meteorological data are more likely to be available.
منابع مشابه
Influence of sampler configuration on the uptake kinetics of a passive air sampler.
Passive air samplers (PAS) are simple and cost-effective tools to monitor semivolatile organic compounds in air. Chemical uptake occurs by molecular diffusion from ambient air to a passive sampling medium (PSM). Previous calibration studies indicate that even for the same type of PAS, passive air sampling rates (R, m(3)(air)/d) can be highly variable due to the influence of a number of factors....
متن کاملCalibration and application of a passive air sampler (XAD-PAS) for volatile methyl siloxanes.
Because the atmosphere is key to understanding the environmental behavior of volatile methyl siloxanes (VMS), a variety of reliable air sampling methods are needed. The purpose of this study was to calibrate and evaluate an existing, polystyrene-divinylbenzene copolymeric resin-based passive air sampler (XAD-PAS) for VMS. Sixteen XAD-PAS were deployed for 7-98 days at a suburban site in Toronto...
متن کاملCharacterization and Application of Passive Samplers for Monitoring of Pesticides in Water.
Five different water passive samplers were calibrated under laboratory conditions for measurement of 124 legacy and current used pesticides. This study provides a protocol for the passive sampler preparation, calibration, extraction method and instrumental analysis. Sampling rates (RS) and passive sampler-water partition coefficients (KPW) were calculated for silicone rubber, polar organic chem...
متن کاملOutdoor passive air monitoring of semi volatile organic compounds (SVOCs): a critical evaluation of performance and limitations of polyurethane foam (PUF) disks.
The most commonly used passive air sampler (PAS) (i.e. polyurethane foam (PUF) disk) is cheap, versatile, and capable of accumulating compounds present both in gas and particle phases. Its performance for particle associated compounds is however disputable. In this study, twelve sets of triplicate PUF-PAS were deployed outdoors for exposure periods of 1-12 weeks together with continuously opera...
متن کاملSimultaneous Determination of 17 Pesticide Residues in Rice by GC/MS using a Direct Sample Introduction Procedure and Spiked Calibration Curves
A reliable, rapid and accurate method based on spiked calibration curves and direct sample introduction was developed for determination of 17 pesticide residues in rice by gas chromatography-mass spectrometry single quadrupole selected ion monitoring GC/MS-SQ-SIM. Sample preparation is based on extraction with acetonitrile without clean up. The use of spiked calibration curves for constructing...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Environmental science. Processes & impacts
دوره 17 7 شماره
صفحات -
تاریخ انتشار 2015