Assessment of coronary arterial restenosis with phase-contrast magnetic resonance imaging measurements of coronary flow reserve.

نویسندگان

  • W G Hundley
  • L D Hillis
  • C A Hamilton
  • R J Applegate
  • D M Herrington
  • G D Clarke
  • G A Braden
  • M S Thomas
  • R A Lange
  • R M Peshock
  • K M Link
چکیده

BACKGROUND After successful percutaneous coronary arterial revascularization, 25% to 60% of subjects have restenosis, a recurrent coronary arterial narrowing at the site of the intervention. At present, restenosis is usually detected invasively with contrast coronary angiography. This study was performed to determine if phase-contrast MRI (PC-MRI) could be used to detect restenosis noninvasively in patients with recurrent chest pain after percutaneous revascularization. METHODS AND RESULTS Seventeen patients (15 men, 2 women, age 36 to 77 years) with recurrent chest pain >3 months after successful percutaneous intervention underwent PC-MRI measurements of coronary artery flow reserve followed by assessments of stenosis severity with computer-assisted quantitative coronary angiography. The intervention was performed in the left anterior descending coronary artery in 15 patients, one of its diagonal branches in 2 patients, and the right coronary artery in 1 patient. A PC-MRI coronary flow reserve value /=70% and >/=50%, respectively. CONCLUSIONS Assessments of coronary flow reserve with PC-MRI can be used to identify flow-limiting stenoses (luminal diameter narrowings >70%) in patients with recurrent chest pain in the months after a successful percutaneous intervention.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of coronary flow velocity reserve using fast velocity-encoded cine MRI for noninvasive detection of restenosis after coronary stent implantation.

PURPOSE Serial change of the coronary flow velocity reserve was evaluated with fast velocity-encoded cine magnetic resonance imaging (MRI) for noninvasive detection of restenosis after coronary stent implantation. METHOD In total, 60 MRI flow studies were performed in 10 patients with coronary artery disease who undersvent elective successful stent implantation to the lesion in the proximal l...

متن کامل

Noninvasive determination of coronary blood flow velocity with cardiovascular magnetic resonance in patients after stent deployment.

BACKGROUND In patients with coronary artery stents, no direct noninvasive coronary artery imaging is possible with magnetic resonance (MR). A well-established method for the assessment of the functional significance of a coronary lesion is the measurement of coronary flow reserve by invasive intracoronary Doppler. The purpose of the study was to determine coronary flow velocity reserve (CFVR) w...

متن کامل

Visualization and functional assessment of proximal and middle left anterior descending coronary stenoses in humans with magnetic resonance imaging.

BACKGROUND Coronary artery bypass grafting improves survival in patients with >70% luminal diameter narrowing of the 3 major epicardial coronary arteries, particularly if there is involvement of the proximal portion of the left anterior descending (LAD) coronary artery. Measurement of coronary flow reserve can be used to identify functionally important luminal narrowing of the LAD artery. Altho...

متن کامل

Assessment of coronary flow reserve: comparison between contrast-enhanced magnetic resonance imaging and positron emission tomography.

OBJECTIVES The study compared flow reserve indices by magnetic resonance imaging (MRI) with quantitative measures of coronary angiography and positron emission tomography (PET). BACKGROUND The noninvasive evaluation of myocardial flow by MRI has recently been introduced. However, a comparison to quantitative flow measurement as assessed by PET has not been reported in patients with coronary a...

متن کامل

Validation of a high-resolution, phase contrast cardiovascular magnetic resonance sequence for evaluation of flow in coronary artery bypass grafts.

The aim was to validate a magnetic resonance high-resolution, phase-contrast sequence for quantifying flow in small and large vessels and to demonstrate its feasibility to measure flow in coronary artery bypass grafts. A breathhold, echo planar imaging (EPI) sequence was developed and validated in a flow phantom using a fast field echo (FFE) sequence as reference. In 17 volunteers aortic flow w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 101 20  شماره 

صفحات  -

تاریخ انتشار 2000