Scanned carbon beam irradiation of moving films: comparison of measured and calculated response

نویسندگان

  • Christoph Bert
  • Daniel Richter
  • Marco Durante
  • Eike Rietzel
چکیده

BACKGROUND Treatment of moving target volumes with scanned particle beams benefits from treatment planning that includes the time domain (4D). Part of 4D treatment planning is calculation of the expected result. These calculation codes should be verified against suitable measurements. We performed simulations and measurements to validate calculation of the film response in the presence of target motion. METHODS All calculations were performed with GSI's treatment planning system TRiP. Interplay patterns between scanned particle beams and moving film detectors are very sensitive to slight deviations of the assumed motion parameters and therefore ideally suited to validate 4D calculations. In total, 14 film motion parameter combinations with lateral motion amplitudes of 8, 15, and 20 mm and 4 combinations for lateral motion including range changes were used. Experimental and calculated film responses were compared by relative difference, mean deviation in two regions-of-interest, as well as line profiles. RESULTS Irradiations of stationary films resulted in a mean relative difference of -1.52% ± 2.06% of measured and calculated responses. In comparison to this reference result, measurements with translational film motion resulted in a mean difference of -0.92% ± 1.30%. In case of irradiations incorporating range changes with a stack of 5 films as detector the deviations increased to -6.4 ± 2.6% (-10.3 ± 9.0% if film in distal fall-off is included) in comparison to -3.6% ± 2.5% (-13.5% ± 19.9% including the distal film) for the stationary irradiation. Furthermore, the comparison of line profiles of 4D calculations and experimental data showed only slight deviations at the borders of the irradiated area. The comparisons of pure lateral motion were used to determine the number of motion states that are required for 4D calculations depending on the motion amplitude. 6 motion states per 10 mm motion amplitude are sufficient to calculate the film response in the presence of motion. CONCLUSIONS By comparison to experimental data, the 4D extension of GSI's treatment planning system TRiP has been successfully validated for film response calculations in the presence of target motion within the accuracy limitation given by film-based dosimetry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic Response of an Axially Moving Viscoelastic Timoshenko Beam

In this paper, the dynamic response of an axially moving viscoelastic beam with simple supports is calculated analytically based on Timoshenko theory. The beam material property is separated to shear and bulk effects. It is assumed that the beam is incompressible in bulk and viscoelastic in shear, which obeys the standard linear model with the material time derivative. The axial speed is charac...

متن کامل

Comparison of Electron-Beam Dose Distributions in a Heterogeneous Phantom Obtained Using Radiochromic Film Dosimetry and Monte Carlo Simulation

Introduction: Nowadays new radiochromic films have an essential role in radiotherapy dosimetry. Properties such as high sensitivity, good reproducibility, high spatial resolution, easy readout and portability have made them attractive for dosimetry, especially in high-dose-gradient regions. Material and Methods: In this study, electron-beam dose distributions in homogenous and heterogeneous pha...

متن کامل

A Patient-specific Qa Procedure for Moving Target Irradiation in Scanned Ion Therapy

Three-dimensional (3D) pencil-beam scanning technique has been utilized since 2011 in NIRS-HIMAC. Beam delivery system and treatment planning software (TPS) require dosimetric patient-specific QA to check each individual plan. Any change in the scanned beams will result in a significant impact on the irradiation dose. Therefore, patient-specific QA for moving target irradiation requires additio...

متن کامل

Physical Nonlinear Analysis of a Beam Under Moving Harmonic Load

A prismatic beam made of a behaviorally nonlinear material is analyzed under aharmonic load moving with a known velocity. The vibration equation of motion is derived usingHamilton principle and Euler-Lagrange Equation. The amplitude of vibration, circular frequency,bending moment, stress and deflection of the beam can be calculated by the presented solution.Considering the response of the beam,...

متن کامل

Experimental investigation of dosimetry response of nanocomposite of polystyrene-multiwall carbon nanotube in gamma radiation field

Recently, polymeric nanocomposites have been used as real-time detectors and dosimeters of gamma radiation. In this experimental work, multi-wall carbon nanotubes (MWCNT) were dispersed in polystyrene (PS) martix with a weight percentage of 0.05 wt%. SEM images confirmed the appropriate and uniform distribution of carbon nanotubes in the polymer matrix. The dark current and photocurrent of the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012