Cardioversion and "false positive" technetium-99m stannous pyrophosphate myocardial scintigrams.
نویسندگان
چکیده
The present studies performed in experimental animals demonstrate that electrical direct current cardioversion can produce skeletal muscle damage and increased technetium-99m stannous pyrophosphate (99mTc-PYP) uptake; in experimental animals the electrically damaged skeletal muscle shows necrosis with extensive calcium deposition. In addition, the frequent administration of high energy cardioversion produces myocardial necrosis with calcium deposition, increased 99mTc-PYP myocardial uptake and a positive 99mTc-PYP myocardial scintigram. The data indicate that, if diagnostic 99mTc-PYP myocardial scintigraphy is contemplated after cardioversion, paddle placement should be slightly removed from the anteroposterior projection of the heart on the external chest wall to avoid possible subsequent confusion between increased myocardial and skeletal muscle uptake of 99mTc-PYP. If multiple high energy cardioversion episodes are necessary, myocardial necrosis resulting from electrical injury may occur and be responisble for increased myocardial uptake of 99mTc-PYP with a resultant positive 99mTc-PYP myocardial scintigram.
منابع مشابه
Technetium stannous pyrophosphate myocardial scintigrams in patients with chest pain of varying etiology.
Technetium-99m stannous pyrophosphate was utilized for myocardial imaging in 202 patients admitted to the hospital with chest pain of uncertain etiology. One hundred and one patients had clinical and evolved electrocardiographic and enzymatic evidence of acute myocardial infarction. Ninety-six of these 101 patients had increased myocardial uptake of the technetium stannous pyrophosphate and pos...
متن کاملTechnetium - 99 m Stannous Pyrophosphate Myocardial Scintigraphy after Cardiopulmonary Resuscitation with Cardioversion RICHARD
Thirty consecutive patients underwent technetium-99m stannous pyrophosphate myocardial scintigraphy 48-72 hours after successful cardiopulmonary resuscitation and direct current cardioversion. Five patients with transmural myocardial infarctions by ECG and enzyme determinations were correctly identified by scintigraphy. Myocardial scans were positive in five of nine patients with nontransmural ...
متن کاملClinicopathologic Study of Persistently Positive Technetium-99m Stannous Pyrophosphate Myocardial Scintigrams and Myocytolytic Degeneration After Myocardial Infarction
In a select series of 46 patients studied by serial myocardial scintigraphy, 19 (41%) retained persistent, usually low grade (2+) positive technetium-99m stannous pyrophosphate ('9mTc-PYP) myocardial scintigrams for at least 3 months after acute myocardial infarction. The one major difference between patients with positive and negative postinfarct 59mTc-PYP myocardial scintigrams was a more sym...
متن کاملTechnetium-99m stannous pyrophosphate myocardial scintigraphy after cardiopulmonary resuscitation with cardioversion.
Thirty consecutive patients underwent technetium-99m stannous pyrophosphate myocardial scintigraphy 48--72 hours after successful cardiopulmonary resuscitation and direct current cardioversion. Five patients with transmural myocardial infarctions by ECG and enzyme determinations were correctly identified by scintigraphy. Myocardial scans were positive in five of nine patients with nontransmural...
متن کاملTechnetium-99m stannous pyrophosphate scintigraphy in patients with calcification within the cardiac silhouette.
Technetium-99m stannous pyrophosphate scintiscanning was performed in 22 patients with radiographically detected calcification within the cardiac silhouette. All but one of these scintigrams showed a localised area of increased activity similar to that ordinarily seen in acute myocardial infarction. Scintiscans in 3 patients after removal of the calcified aortic valve reverted to negative. It w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 54 3 شماره
صفحات -
تاریخ انتشار 1976