Field-based evaluation of a reagent strip test for diagnosis of Schistosoma mansoni by detecting circulating cathodic antigen in urine before and after chemotherapy.

نویسندگان

  • Mengistu Legesse
  • Berhanu Erko
چکیده

The sensitivity of a reagent strip test for the diagnosis of schistosomiasis by detecting circulating cathodic antigen (CCA) in urine was evaluated under field conditions using 251 stool and urine samples collected from a Schistosoma mansoni-endemic area of Ethiopia. The specificity of the test was evaluated in an area where schistosomiasis is not endemic. Stool samples were examined microscopically using duplicate Kato slides and formol-ether concentration methods. The effectiveness of the test in monitoring efficacy was also evaluated following chemotherapy. The results revealed that detection of CCA in urine using the one-step reagent strip test was superior to the stool examination methods (P<0.05) in indicating the prevalence of the disease. Assuming the combination of parasitological test results as the gold standard, the sensitivity and specificity of the test were 82.1% and 75.9%, respectively. The results of egg counts suggested the potential use of urine CCA in indicating the intensity of infection as an alternative to parasitological methods. The sensitivity and specificity of the test were 75% and 73.7%, respectively, following chemotherapy. Diagnosis of S. mansoni infection in urine using reagent strips would provide information on the prevalence of the disease, although further study is needed to improve its sensitivity and specificity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Field-based evaluation of a reagent strip test for diagnosis of schistosomiasis mansoni by detecting circulating cathodic antigen (CCA) in urine in low endemic area in Ethiopia.

The sensitivity, specificity, positive and negative predictive values of a reagent strip test for the diagnosis of schistosomiasis mansoni by detecting circulating cathodic antigen (CCA) in urine were evaluated using 184 stool and urine samples collected from schoolchildren living in relatively low endemic area of schistosomiasis mansoni in Ethiopia. A combined result of stool samples processed...

متن کامل

Validation of a Point-of-Care Circulating Cathodic Antigen Urine Cassette Test for Schistosoma mansoni Diagnosis in the Sahel, and Potential Cross-Reaction in Pregnancy.

On the shores of Lake Chad, schistosomiasis among mobile pastoralists was investigated in a field laboratory. Point-of-care circulating cathodic antigen (POC-CCA) cassette test, reagent strip, and filtration were conducted on urine samples. Fresh stool samples were subjected to the Kato-Katz technique, and fixed samples were examined with an ether-concentration method at a reference laboratory....

متن کامل

Rapid diagnosis of schistosomiasis by antigen detection in urine with a reagent strip.

For the rapid and simple diagnosis of schistosomiasis, a reagent strip assay for detection of circulating cathodic antigen (CCA) in urine was developed. The test was based on a previously developed sandwich enzyme-linked immunosorbent assay (ELISA) using a combination of two anti-CCA monoclonal antibodies. For the reagent strip assay, as the capture matrix, monoclonal antibody was coated onto a...

متن کامل

Evaluation of Circulating Cathodic Antigen (CCA) Urine-Tests for Diagnosis of Schistosoma mansoni Infection in Cameroon

BACKGROUND The Kato-Katz is the most common diagnostic method for Schistosoma mansoni infection. However, the day-to-day variability in host egg-excretion and its low detection sensitivity are major limits for its use in low transmission zones and after widespread chemotherapy. We evaluated the accuracy of circulating cathodic antigen (CCA) urine-assay as a diagnostic tool of S. mansoni. In com...

متن کامل

Use of circulating cathodic antigen strips for the diagnosis of urinary schistosomiasis.

Rapid diagnostic tests are needed for the implementation and monitoring of national schistosomiasis control programmes. The field applicability of the circulating cathodic antigen (CCA) urine reagent strip for the diagnosis of Schistosoma haematobium infection was evaluated among 265 pre- and primary schoolchildren aged 2-19 years in a rural area of Zimbabwe. The CCA strip was compared with egg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Transactions of the Royal Society of Tropical Medicine and Hygiene

دوره 101 7  شماره 

صفحات  -

تاریخ انتشار 2007