Left atrial and left atrial appendage 4D blood flow dynamics in atrial fibrillation

نویسندگان

  • Michael Markl
  • Charles Foucar
  • Maria L Carr
  • Daniel C Lee
  • Jason Ng
  • James C Carr
  • Jeffrey J Goldberger
چکیده

BACKGROUND Atrial 4D flow magnetic resonance imaging was used for the characterization of left atrial (LA) and left atrial appendage (LAA) flow dynamics in patients with atrial fibrillation (AF). METHODS AND RESULTS 4D flow magnetic resonance imaging measured in vivo 3D blood flow velocities in 60 AF patients and 15 controls. Anatomic maps of LA and LAA stasis and velocity were calculated to quantify atrial peak velocity, mean velocity, and stasis (velocities <0.1 m/s). In a substudy with 30 AF patients, 4D flow metrics were compared with Doppler transesophageal echocardiography. For all 15 controls, LAA mean and peak velocities were consistently lower (by 21%/12%; P<0.001) while LAA stasis was higher (by 58%; P<0.001) compared with the LA. In contrast, lower LAA velocity and increased LAA stasis were only found in a fraction (38 of 60) of AF patients. In AF patients, increased CHA2DS2-VASc score was associated with significantly (P<0.043) reduced LA velocities and elevated stasis. There was a heterogeneous expression of atrial flow dynamics, and 25% to 68% of AF patients demonstrated flow in the normal range: 25%/68% for LA/LAA stasis and 38%/60% for LA/LAA peak velocities. Transesophageal echocardiography velocities modestly but significantly (P<0.05) correlated with 4D flow-based LA velocities (r=0.41) and stasis (r=-0.39). CONCLUSIONS AF resulted in overall impaired but individually variable flow dynamics in both the LA and LAA. AF patients demonstrated atrial flow in the normal range, despite elevated CHA2DS2-VASc score.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Semi-Automated Algorithm for Segmentation of the Left Atrial Appendage Landing Zone: Application in Left Atrial Appendage Occlusion Procedures

Background: Mechanical occlusion of the Left atrial appendage (LAA) using a purpose-built device has emerged as an effective prophylactic treatment in patients with atrial fibrillation at risk of stroke and a contraindication for anticoagulation. A crucial step in procedural planning is the choice of the device size. This is currently based on the manual analysis of the “Device Landing Zone” fr...

متن کامل

Left atrial blood stasis by 4D flow MRI correlates with stroke risk estimation by CHA2DS2-VASc score

Background Stroke is the most serious complication of atrial fibrillation (AF). Of the estimated 600,000 ischemic strokes that occur each year in the United States, 15-20 percent are thought to be secondary to AF. Blood stasis is a key factor responsible for thrombus formation in the left atrium (LA). Studies utilizing transesophageal echocardiography have shown that peak left atrial appendage ...

متن کامل

Assessment of left atrial and left atrial appendage flow and stasis in atrial fibrillation

Background Atrial fibrillation (AF) is associated with increased risk of stroke due to development of left atrial (LA) thrombus [1]. Thromboembolic risk is assessed by clinical risk scores (CHA2DS2-VASc). However, these scores have limited predictive value. Echocardiography studies have shown that physiologic factors such as decreased atrial blood flow and increased stasis (LA velocities <0.2m/...

متن کامل

LA velocities and stasis assessed by 4D flow MRI are closely associated with LAA peak velocities by Doppler TEE in patients with atrial fibrillation

Background Atrial fibrillation (AF) is associated with increased risk of stroke due to development of left atrial (LA) thrombus [1]. Studies utilizing transesophageal echocardiography (TEE) have shown that decreased peak emptying flow velocity in the LA appendage (LAA) in patients with AF is a risk factor for stroke [2,3]. As a non-invasive alternative, 4D flow MRI can measure 3D blood flow vel...

متن کامل

Left Atrial 4D Blood Flow Dynamics and Hemostasis following Electrical Cardioversion of Atrial Fibrillation

Background: Electrical cardioversion in patients with atrial fibrillation is followed by a transiently impaired atrial mechanical function, termed atrial stunning. During atrial stunning, a retained risk of left atrial thrombus formation exists, which may be attributed to abnormal left atrial blood flow patterns. 4D Flow cardiovascular magnetic resonance (CMR) enables blood flow assessment from...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2016