A colorimetric sensor array for detection and identification of sugars.

نویسندگان

  • Sung H Lim
  • Christopher J Musto
  • Erwin Park
  • Wenxuan Zhong
  • Kenneth S Suslick
چکیده

Molecular recognition of sugars and a practical method to detect and discriminate among a large number of such similar analytes remain substantial scientific challenges. We report here a low-cost, simple colorimetric sensor array capable of identification and quantification of sugars and related compounds. Fifteen different monosaccharides, disaccharides, and artificial sweeteners were differentiated without error in 80 trials. Limits of detection at pH 7.4 for glucose were <1 mM, which is below physiologically important levels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preoxidation for colorimetric sensor array detection of VOCs.

A disposable preoxidation technique that dramatically improves the detection and identification of volatile organic compounds (VOCs) by a colorimetric sensor array is reported. Passing a vapor stream through a tube packed with chromic acid on silica immediately before the colorimetric sensor array substantially increases the sensitivity to less-reactive VOCs and improves the limits of detection...

متن کامل

Colorimetric sensor array allows fast detection and simultaneous identification of sepsis-causing bacteria in spiked blood culture.

Sepsis is a medical emergency demanding early diagnosis and tailored antimicrobial therapy. Every hour of delay in initiating effective therapy measurably increases patient mortality. Blood culture is currently the reference standard for detecting bloodstream infection, a multistep process which may take one to several days. Here, we report a novel paradigm for earlier detection and the simulta...

متن کامل

Colorimetric Sensor Array Allows Earlier Detection and Simultaneous Identification of Sepsis-

28 29 Sepsis is a medical emergency demanding early diagnosis and tailored antimicrobial therapy. 30 Every hour of delay in effective therapy measurably increases mortality. Blood culture is currently the 31 reference standard for diagnosing bloodstream infection, a multistep process which may take one to 32 several days. Here, we report a novel paradigm for earlier detection and simultaneous i...

متن کامل

A colorimetric sensor array for identification of toxic gases below permissible exposure limits.

A colorimetric sensor array has been developed for the rapid and sensitive detection of 20 toxic industrial chemicals (TICs) at their PELs (permissible exposure limits). The color changes in an array of chemically responsive nanoporous pigments provide facile identification of the TICs with an error rate below 0.7%.

متن کامل

Colorimetric sensor array for determination and identification of toxic industrial chemicals.

A low-cost yet highly sensitive colorimetric sensor array for the detection and identification of toxic industrial chemicals (TICs) has been developed. The sensor consists of a disposable array of cross-responsive nanoporous pigments whose colors are changed by diverse chemical interactions with analytes. Clear differentiation among 20 different TICs has been easily achieved at both their IDLH ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Organic letters

دوره 10 20  شماره 

صفحات  -

تاریخ انتشار 2008