Detection of interrupted bubble flow in the Technicon automated immunoprecipitin system.

نویسندگان

  • R J Hansen
  • A R Tschida
  • H Markowitz
چکیده

In an automated immunoprecipitin system for analysis of serum immunoglobulins (Technicon Instruments Corp., Tarrytown, N.Y. 10591) (1, 2) sampler lines of small inside diameter (0.0075 and 0.020 inch) must be used, and so flow is occasionally interrupted when the line becomes blocked by particulate matter. Cleaning the blocked line is simple; however, flow interruption is detected only by carefully observing the sampler probe line for lack of bubble flow when the probe switches between samples. Thus continuous operator attention is required; otherwise time and costly antiserum are lost before blockage is detected. This note describes a simple system that promptly warns the operator that the sampler probe line is blocked. Because the sampler probe picks up a new sample every 1.2 mm (50, 1/1 cam), an air bubble flows through the sampler probe every 0.6 mm. With the present accessory, the passage of each bubble is used as a signalto triggera retriggerablemonostable multivibratorwith a delay time greaterthan the bubble separation time. During normal operation the bubble pattern continues to trigger the monostable multivibrator and no change of logic state will appear at its output terminal. Should the flow pattern stop for any reason, after 1.4 mm a “Sonalert” alarm will sound.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated method for screening urine for amphetamine and some related primary amines.

601 Simplified Serum Phosphorus Analyses by Continuous-Flow Ultraviolet Spectrophotometry Elias Amador and Jackie Urban 605 Estimation of Normal Ranges and Cumulative Proportions by Transforming Observed Distributions to Gaussian Form Eugene K. Harris and David L. DeMets 613 Urinary Cystathionine, Catecholamine, and Metabolites in Patients with Neuroblastoma L. Helson, M. Fleisher, V. Bethune, ...

متن کامل

Automated immunoprecipitin technique for analysis of the third component of complement (C'3) in human serum.

Shands Teaching Hospital, Gainesville, FIa. 32601. 1 NIH Academic Pathology trainee, Department of Pathology, J. Hillis Miller Health Center, University of Florida, Gainesville, Florida, 32601. ‘Alper, C. A., Automated nephelometric determination of serum haptoglobin, C3 and ai-antitrypsin, Abstract 43; Fish, M. B., Aronson, S. B., and Wegfhart, P., Specific quantitation of serum albumin by con...

متن کامل

Survey on Perception of People Regarding Utilization of Computer Science & Information Technology in Manipulation of Big Data, Disease Detection & Drug Discovery

this research explores the manipulation of biomedical big data and diseases detection using automated computing mechanisms. As efficient and cost effective way to discover disease and drug is important for a society so computer aided automated system is a must. This paper aims to understand the importance of computer aided automated system among the people. The analysis result from collected da...

متن کامل

Retrieval–travel-time model for free-fall-flow-rack automated storage and retrieval system

Automated storage and retrieval systems (AS/RSs) are material handling systems that are frequently used in manufacturing and distribution centers. The modelling of the retrieval–travel time of an AS/RS (expected product delivery time) is practically important, because it allows us to evaluate and improve the system throughput. The free-fall-flow-rack AS/RS has emerged as a new technology for dr...

متن کامل

Experimental investigation of bubble growth and detachment in stagnant liquid column using image – based analysis

An experimental study has been carried out to characterize bubble formation, growth, and detachment mechanisms in a stagnant liquid column. Both bubble frequency and bubble detachment size were measured in different gas flow rates, injector diameters and orientations, submergence height, and liquid properties. Experiments were performed for air injection flow rate ranges between 200 mlph and 12...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 18 7  شماره 

صفحات  -

تاریخ انتشار 1972