A method to measure cervical spine motion over extended periods of time.

نویسندگان

  • Faiz I Syed
  • Ashish L Oza
  • Ray Vanderby
  • Bryan Heiderscheit
  • Paul A Anderson
چکیده

STUDY DESIGN System validation study. OBJECTIVE To develop and validate a motion sensor system for measuring cervical spine motion over extended time periods. SUMMARY OF BACKGROUND DATA Many studies using different methodologies have tried to estimate cervical spine motion. These have mostly been carried out in a laboratory setting performing active/passive range of motion or activities of daily living. However, cervical spine performance over extended periods of time in natural environments remains unknown. METHODS A novel motion sensor system, Wisconsin Analysis of Spine Motion Performance (WASP), was validated using 2 benchmarks: a materials testing machine (MTS) and optical motion tracking laboratory. Parameters tested included drift, frequency response, accuracy, effect of sensor orientation, and coupled motions. Applied motions from the MTS and measured motions in subject volunteers under various conditions were compared with WASP using correlation coefficients. Intersubject and intrasubject variability analyses for WASP were also performed. RESULTS The average WASP slopes for accuracy (compared with MTS) in flexion-extension, lateral bending, and axial rotation were 0.89, 0.93, and 0.38, respectively. The correlation coefficient was 0.99 in all cases. Compared with optical motion tracking, the WASP regression slopes were 1.1, 1.02, and 0.4 and the correlation coefficients were 0.98, 0.92, and 0.93 in the 3 axes of motion. Coupled motion was noted during all subject motions. WASP peak detection algorithm had a 0% error discounting boundary conditions. CONCLUSION WASP was accurate in flexion-extension and lateral bending. In axial rotation, WASP was less accurate. However, the system was highly reliable with low intersubject and intrasubject variability. WASP can be used in estimating cervical spine motion with high reliability while keeping in mind the decreased accuracy in measuring axial rotation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predicting the Risk of Hearing Impairment Following the Cervical Spine Diseases by Measuring the Cervical Range of Movements: A Pilot Study

Introduction: Cervical spine abnormalities can affect the ear vessels and or nerves with different mechanisms. Ear dysfunctions following cervical spine injuries can be manifested as hearing loss, vertigo, or tinnitus. Usually, cervical spine injuries can cause pain and Range of Motion (ROM) limitation. The major objective of this study was to determine which cervical ROM limitation was accompa...

متن کامل

Effects Analysis of Frozen Conditions for Spacecraft Relative Motion Dynamics

The purpose of this rersearch is to analyze the effective application of particular earth orbits in dynamical modeling of relative motion problem between two spacecraft. One challenge in implementing these motions is maintaining the relations as it experiences orbital perturbations (zonal harmonics J2 and J3), most notably due to the Earth’s oblateness. Certain aspects of the orbital geometry c...

متن کامل

Assessment of the cervical range of motion over time, differences between results of the Flock of Birds and the EDI-320: a comparison between an electromagnetic tracking system and an electronic inclinometer.

The objective of this study was to analyse cervical range of motion, assessed over time by means of a digital inclinometer (EDI-320) and a three-dimensional electromagnetic tracking device (Flock of Birds). The maximum active cervical range of motion was assessed with two measurement devices in three sessions over time, with 6-week intervals. In total, 26 women and 24 men (mean age: 44.4, SD: 9...

متن کامل

Three-dimensional change in the cervical spine in a cross-legged sitting position after a time lapse

[Purpose] The purpose of this study was to investigate the kinematic changes of the cervical spine during cross-legged sitting. [Subjects and Methods] In total, 19 healthy participants were recruited from among healthy students of Silla University. Each participant sat cross-legged with the right leg over the left and gazed at a target presented at 45° below the horizontal line of sight or at a...

متن کامل

Variation in the cervical range of motion over time measured by the "flock of birds" electromagnetic tracking system.

STUDY DESIGN Observational longitudinal study. OBJECTIVE To establish the normal variation over time for active and passive cervical range of motion (ROM) measured with the Flock of Birds electromagnetic tracking system (FOB). SUMMARY OF BACKGROUND DATA Data about normal variation of cervical ROM over time are scarce but important for the interpretation of study results. METHODS Forty-eig...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Spine

دوره 32 19  شماره 

صفحات  -

تاریخ انتشار 2007