Lack of requirement for blind subcultures of BACTEC blood culture media.

نویسندگان

  • J C McLaughlin
  • J L Evers
  • J L Officer
چکیده

To determine the need for blind subculturing of BACTEC (Johnston Laboratories, Cockeysville, Md.) blood culture media, we compared results of radiometric readings, visual inspection, and blind subculturing for nearly 7,500 blood specimens. Visual inspection and radiometric testing were performed on day 1 through 7, and blind subcultures were made on day 3. In the first phase of the study, 402 of 3,896 aerobic bottles were positive by radiometric testing (growth index, greater than 25), visual inspection, or subculturing. Only six bottles were radiometrically negative but subculture positive on day 3. The second phase of the study was designed to determine if aerobic bottles eventually became radiometrically positive in those cases in which they were radiometrically negative but subculture positive on day 3. Two bottles were subculture positive but never gave a growth index of greater than or equal to 25 by day 7. One yielded Staphylococcus epidermidis, and one yielded viridans, Streptococcus sp. A total of 35 anaerobic organisms were isolated from 3,896 blood specimens. All of these anaerobes were detected by both radiometric testing and subculturing. We examined a total of 14,972 blood culture bottles. Twenty-nine bottles considered negative by visual inspection or radiometric readings were found to be positive by subculturing. Fifteen of these were shown, by chart review, to contain contaminants. Organisms in the other negative bottles would not have gone undetected because companion bottles from the same patients were radiometrically or visually positive. We concluded that it is necessary to perform blind subcultures of BACTEC 7B and 8B blood culture bottles.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تشخیص بروسلوز با استفاده از سیستم کشت خون ‌ BACTECو تائید نتایج آن با PCR

Abstract: Brucellosis is one of the most common zoonotic diseases in Iran. Growth of Brucella is slow and blood cultures of these bacteria are time-consuming via classical methods. We try to evaluate BACTEC 9120 system capacity in order to detect of bacteremia due to Brucella spp and to confirm isolated bacteria by PCR. Blood culture sample of 102 suspected patients evaluated by BACTEC 9120 sys...

متن کامل

Valuable of terminal subcultures from negative BACTEC blood culture bottles.

Terminal subcultures from 5,354 negative BACTEC blood culture bottles did not significantly improve the detection of positive cultures. Only 15 of the 545 total isolates were recovered from the terminal subcultures. All 15 of these isolates were either considered contaminants or had been previously detected.

متن کامل

A comparison of costs and effectiveness of the BACTEC NR-730 system and a conventional method of blood culture.

Results and costs of the first six months experience with BACTEC NR-730 were compared with a series of blood cultures performed by the conventional method previously used. The newer technology detected the growth of 14.1% of significant isolates on the day of receipt of the specimens. The previous method lacked blind subcultures on the day of receipt and therefore detected growth only after ove...

متن کامل

Acridine orange staining and radiometric detection of microorganisms in blood cultures.

To determine whether acridine orange (AO) staining of blood cultures could be used as a substitute for blind subculture when used in conjunction with the BACTEC system (Johnston Laboratories, Inc., Towson, Md.), the two methods were compared on all BACTEC-negative specimens. Since blind subcultures were routinely performed in our laboratory on days 2 and 6 of incubation, AO staining was also pe...

متن کامل

Controlled evaluation of supplemented peptone and Bactec blood culture broths for the detection of bacteremia and fungemia.

Comparison of conventional blood culture media with newer formulations of Bactec media for radiometric detection are lacking. Therefore, we compared the yield and speed of detection of clinically important microorganisms with supplemented peptone broth (SPB) and Bactec aerobic (6B) and anaerobic (7C or 7D) broths in 7,627 blood samples from adult patients. Acridine orange stains from SPB, radio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 14 5  شماره 

صفحات  -

تاریخ انتشار 1981