Scan Time Optimization for Post-injection PET Scans
نویسندگان
چکیده
Previous methods for optimizing the scan times for PET transmission and emission scans under a total scan time constraint were based on linear non-statistical methods and used noise equivalent counts (NEC) criteria. The scan times determined by NEC analysis may be suboptimal when nonlinear statistical image reconstruction methods are used. For statistical image reconstruction, the predicted variance in selected regions of interest is an appropriate alternative to NEC analysis. We propose a new method for optimizing the relative scan times (fractions) based on analytical approximations to the covariance of images reconstructed by both conventional and penalized-likelihood methods. We perform simulations to compare predicted standard deviations with empirical ones. Results show that for statistical transmission image reconstruction, the optimal fraction of the scan time devoted to transmission scanning is shorter than for conventional transmission smoothing.
منابع مشابه
Statistical Image Reconstruction Methods for Simultaneous Emission/Transmission PET Scans
Transmission scans are necessary for estimating the attenuation correction factors (ACFs) to yield quantitatively accurate PET emission images. To reduce the total scan time, postinjection transmission scans have been proposed in which one can simultaneously acquire emission and transmission data using rod sources and sinogram windowing. However, since the post-injection transmission scans are ...
متن کاملDual time point imaging fluorine-18 flourodeoxyglucose positron emission tomography for evaluation of large loco-regional recurrences of breast cancer treated with electrochemotherapy
BACKGROUND Electrochemotherapy is a local anticancer treatment very efficient for treatment of small cutaneous metastases. The method is now being investigated for large cutaneous recurrences of breast cancer that are often confluent masses of malignant tumour with various degrees of inflammation. To this end 18-Flourine-Flourodeoxyglucose-Positron Emission Tomography/Computed Tomography (FDG-P...
متن کاملStandard PET imaging protocols and phantom test procedures and criteria: executive summary
The standard protocols described in this document cover subject preparation, injection activity, accumulation time, subject positioning, scan time and the criteria for determination of reconstruction parameters for each PET camera based on phantom data. The idea is to standardize the methods and conditions that would affect the PET image qualitatively or quantitatively. However, the image quali...
متن کاملAccuracy of cardiac PET imaging using post-injection transmission scan.
UNLABELLED The purpose of this study was to investigate the accuracy of cardiac PET with post-injection transmission scans. METHODS We performed a phantom study using 18F solution as well as 13N-ammonia PET study of ten patients. The average activities of no myocardial defect phantom model were estimated, and myocardial defect sizes of 12 phantom models were measured by pre- and post-injectio...
متن کاملIntrasubject correlation between static scan and distribution volume images for [11C]flumazenil PET.
Accumulation of [11C]flumazenil (FMZ) reflects central nervous system benzodiazepine receptor (BZR). We searched for the optimal time for a static PET scan with FMZ as semi-quantitative imaging of BZR distribution. In 10 normal subjects, a dynamic series of decay-corrected PET scans was performed for 60 minutes, and the arterial blood was sampled during the scan to measure radioactivity and lab...
متن کامل