Understanding the Correlation between Tomographic and Biomechanical Severity of Keratoconic Corneas
نویسندگان
چکیده
Purpose. To evaluate correlation between tomographic gradation of keratoconus (KC) and its corresponding air-puff induced biomechanical response. Methods. Corneal tomography and biomechanics were measured with Scheimpflug imaging in 44 normal and 92 KC corneas. Deformation waveform was also analyzed with Fourier series. A custom KC severity scale was used from 1 to 3 with 3 as the most severe grade. Tomographic and biomechanical variables were assessed among the grades. Sensitivity and specificity of the variables were assessed using receiver operating characteristics (ROC). Results. Curvature variables were significantly different between normal and disease (P < 0.05) and among grades (P < 0.05). Biomechanical variables were significantly different between normal and disease (P<0.05) but similar among grades 1 and 2 (P > 0.05). All variables had an area under the ROC curve greater than 0.5. The root mean square of the Fourier cosine coefficients had the best ROC (0.92, cut-off: 0.027, sensitivity: 83%, specificity: 88.6%). Spearman correlation coefficient was significant between most variables (P < 0.05). However, tomographic segregation of keratoconus did not result in concomitant biomechanical segregation of the grades. Conclusions. There was lack of significant biomechanical difference between mild disease grades, despite progressive corneal thinning. Mathematical models that estimate corneal modulus from air-puff deformation may be more useful.
منابع مشابه
Corneal Biomechanical Assessment Using Corneal Visualization Scheimpflug Technology in Keratoconic and Normal Eyes
Purpose. To compare the corneal biomechanical properties of keratoconic patients and age-matched controls using corneal visualization Scheimpflug technology (Corvis ST). Methods. Sixty keratoconic eyes from 47 keratoconus patients and 60 normal eyes from 60 controls were enrolled in this prospective study. Tomography and biomechanical parameters of all eyes were obtained with the Pentacam and C...
متن کاملBiomechanical characterization of keratoconus corneas ex vivo with Brillouin microscopy.
PURPOSE Loss of corneal strength is a central feature of keratoconus progression. However, it is currently difficult to measure corneal mechanical changes noninvasively. The objective of this study is to evaluate if Brillouin optical microscopy can differentiate the mechanical properties of keratoconic corneas versus healthy corneas ex vivo. METHODS We obtained eight tissue samples from healt...
متن کاملCorrelation between epithelial thickness in normal corneas, untreated ectatic corneas, and ectatic corneas previously treated with CXL; is overall epithelial thickness a very early ectasia prognostic factor?
PURPOSE To determine and correlate epithelial corneal thickness (pachymetric) measurements taken with a digital arc scanning very high frequency ultrasound biomicroscopy (HF UBM) imaging system (Artemis-II), and compare mean and central epithelial thickness among normal eyes, untreated keratoconic eyes, and keratoconic eyes previously treated with collagen crosslinking (CXL). METHODS Epitheli...
متن کاملCorneal Pachymetry measured with Pentacam and CorvisST in Normal and Keratoconic Eyes
Purpose: To evaluate the agreement of pachymetry data provided by a new instrument to measure intraocular pressure (IOP) and the corneal biomechanical response with the values provided by Pentacam in healthy and keratoconic eyes. Methods: Fifty-four right eyes from 54 healthy patients (32 females, 22 males) and 82 eyes from 43 keratoconus patients (20 females, 23 males) were included in the stu...
متن کاملComparison of keratometric and pachymetric parameters with Scheimpflug imaging in normal and keratoconic Asian eyes
PURPOSE To evaluate the keratometric and pachymetric parameters of keratoconic corneas of Asian eyes with the Scheimpflug imaging camera. PATIENTS AND METHODS This is a cross-sectional study of 22 eyes with Amsler-Krumeich stage 1 keratoconus and 48 eyes from normal subjects conducted in a tertiary eye hospital. A rotating Scheimpflug imaging system, the Pentacam, was used to evaluate all eye...