Second order motion compensated spin-echo diffusion tensor imaging of the human heart
نویسندگان
چکیده
PURPOSE Myocardial microstructure has been challenging to probe in vivo. Spin echo-based diffusion-weighted sequences allow for single-shot acquisitions but are highly sensitive to cardiac motion. In this study, the use of second-order motion-compensated diffusion encoding was compared with first-order motion-compensated diffusion-weighted imaging during systolic contraction of the heart. METHODS First- and second-order motion-compensated diffusion encoding gradients were incorporated into a triggered single-shot spin echo sequence. The effect of contractile motion on the apparent diffusion coefficients and tensor orientations was investigated in vivo from basal to apical level of the heart. RESULTS Second-order motion compensation was found to increase the range of systolic trigger delays from 30%-55% to 15%-77% peak systole at the apex and from 25%-50% to 15%-79% peak systole at the base. Diffusion tensor analysis yielded more physiological transmural distributions when using second-order motion-compensated diffusion tensor imaging. CONCLUSION Higher-order motion-compensated diffusion encoding decreases the sensitivity to cardiac motion, thereby enabling cardiac DTI over a wider range of time points during systolic contraction of the heart.
منابع مشابه
Direct comparison of in-vivo and post-mortem spin-echo based diffusion tensor imaging in the porcine heart
Background Spin-echo based cardiac diffusion tensor imaging (DTI) is highly sensitive to myocardial strain [1]. Imaging during systolic contraction requires precise planning of the sequence timing [2]. Second order motion compensated diffusion encoding has recently been proposed for small animal imaging [3] to reduce the impact of myocardial strain on the diffusion tensor. It is the objective o...
متن کاملSecond order motion compensated spin echo cardiac diffusion tensor imaging on clinical MR systems
Background Recently second order motion compensated spin echo (SE) sequences in conjunction with high performance gradient systems have been proposed for diffusion weighted (DWI) [1] and diffusion tensor imaging (DTI) [2,3] of the human in vivo heart. The method allows for free breathing acquisition without requiring dedicated patient feedback systems or other provisions [4], facilitating the t...
متن کاملSpin echo versus stimulated echo diffusion tensor imaging of the in vivo human heart
PURPOSE To compare signal-to-noise ratio (SNR) efficiency and diffusion tensor metrics of cardiac diffusion tensor mapping using acceleration-compensated spin-echo (SE) and stimulated echo acquisition mode (STEAM) imaging. METHODS Diffusion weighted SE and STEAM sequences were implemented on a clinical 1.5 Tesla MR system. The SNR efficiency of SE and STEAM was measured (b = 50-450 s/mm(2) ) ...
متن کاملIn-vivo cardiac DTI: An initial comparison of M012 compensated spin-echo and STEAM
Background In-vivo cardiac diffusion tensor imaging (cDTI) has been performed using a stimulated echo (STEAM) sequence for 20 years [1]. While short diffusion gradients make it motion insensitive, it is strain sensitive and SNR inefficient. Recently a spin-echo (SE) sequence with velocity and acceleration compensated diffusion gradients was demonstrated in rats [2] and healthy volunteers using ...
متن کاملWhole heart DTI using asymmetric bipolar diffusion gradients
Background Cardiac diffusion weighted imaging (DWI) using a spin echo sequence is challenging because of its high sensitivity to bulk motion. When the displacement or acceleration are constant and coherent but not equal for all spins within a voxel, it will cause signal attenuation due intra voxel de-phasing as an effect of first or second order moment encoding errors. This signal attenuation c...
متن کامل