Automated grading system for evaluation of ocular redness associated with dry eye

نویسندگان

  • John D Rodriguez
  • Patrick R Johnston
  • George W Ousler
  • Lisa M Smith
  • Mark B Abelson
چکیده

BACKGROUND We have observed that dry eye redness is characterized by a prominence of fine horizontal conjunctival vessels in the exposed ocular surface of the interpalpebral fissure, and have incorporated this feature into the grading of redness in clinical studies of dry eye. AIM To develop an automated method of grading dry eye-associated ocular redness in order to expand on the clinical grading system currently used. METHODS Ninety nine images from 26 dry eye subjects were evaluated by five graders using a 0-4 (in 0.5 increments) dry eye redness (Ora Calibra™ Dry Eye Redness Scale [OCDER]) scale. For the automated method, the Opencv computer vision library was used to develop software for calculating redness and horizontal conjunctival vessels (noted as "horizontality"). From original photograph, the region of interest (ROI) was selected manually using the open source ImageJ software. Total average redness intensity (Com-Red) was calculated as a single channel 8-bit image as R - 0.83G - 0.17B, where R, G and B were the respective intensities of the red, green and blue channels. The location of vessels was detected by normalizing the blue channel and selecting pixels with an intensity of less than 97% of the mean. The horizontal component (Com-Hor) was calculated by the first order Sobel derivative in the vertical direction and the score was calculated as the average blue channel image intensity of this vertical derivative. Pearson correlation coefficients, accuracy and concordance correlation coefficients (CCC) were calculated after regression and standardized regression of the dataset. RESULTS The agreement (both Pearson's and CCC) among investigators using the OCDER scale was 0.67, while the agreement of investigator to computer was 0.76. A multiple regression using both redness and horizontality improved the agreement CCC from 0.66 and 0.69 to 0.76, demonstrating the contribution of vessel geometry to the overall grade. Computer analysis of a given image has 100% repeatability and zero variability from session to session. CONCLUSION This objective means of grading ocular redness in a unified fashion has potential significance as a new clinical endpoint. In comparisons between computer and investigator, computer grading proved to be more reliable than another investigator using the OCDER scale. The best fitting model based on the present sample, and usable for future studies, was [Formula: see text] is the predicted investigator grade, and [Formula: see text] and [Formula: see text] are logarithmic transformations of the computer calculated parameters COM-Hor and COM-Red. Considering the superior repeatability, computer automated grading might be preferable to investigator grading in multicentered dry eye studies in which the subtle differences in redness incurred by treatment have been historically difficult to define.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated Grading System for Evaluation of Superficial Punctate Keratitis Associated With Dry Eye

Citation: Rodriguez JD, Lane KJ, Ousler GW III, Angjeli E, Smith LM, Abelson MB. Automated grading system for evaluation of superficial punctate keratitis associated with dry eye. Invest Ophthalmol Vis Sci. 2015;56:2340–2347. DOI:10.1167/ iovs.14-15318 PURPOSE. To develop an automated method of grading fluorescein staining that accurately reproduces the clinical grading system currently in use.

متن کامل

Design and Evaluation of Ocular Controlled Delivery System for Diclofenac Sodium

Diclofenac sodium as ophthalmic dosage form is used in patients treatment of eye pain, swelling and redness recovering from cataract surgery but it faces the bioavailability limitation of eye drops due to effective protective mechanisms and corneal barrier functions in the eyes. Therefore, this investigation was aimed to develop ocular film formulations to achieve controlled drug release. Drug ...

متن کامل

Design and Evaluation of Ocular Controlled Delivery System for Diclofenac Sodium

Diclofenac sodium as ophthalmic dosage form is used in patients treatment of eye pain, swelling and redness recovering from cataract surgery but it faces the bioavailability limitation of eye drops due to effective protective mechanisms and corneal barrier functions in the eyes. Therefore, this investigation was aimed to develop ocular film formulations to achieve controlled drug release. Drug ...

متن کامل

The Ocular Redness Index: a novel automated method for measuring ocular injection.

PURPOSE To develop and validate a novel automated system to assess ocular redness (OR) in clinical images. METHODS We developed a novel software that quantifies OR in digital images based on a mathematic algorithm using a centesimal continuous scoring scale. Subsequently, we conducted a study to validate the scores obtained with this system by correlating them with those obtained by two physi...

متن کامل

Ocular Problems in High-Altitude Traveling: A Review With Focus on Management

Traveling to high altitudes can expose the eye to reduced ambient cold and low-pressure environments. These conditions can affect the physiology of the eye and may result in ocular problems and visual disturbances. In this paper, ocular disorders related to high altitudes are briefly reviewed. Then, high-altitude ocular disorders are categorized in three parts: those related to dry and cold env...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2013