A Nonnegatively Constrained Iterative Method with Statistically Based Stopping Rules for Ct, Pet, and Spect Imaging

نویسندگان

  • JOHNATHAN M. BARDSLEY
  • J. M. Bardsley
چکیده

In this paper, we extend a nonnegatively constrained iterative method and three stopping rules for its iterations to the medical imaging inverse problems of computed tomography (CT), positron emission tomography (PET), and single photon emission computed tomography (SPECT); the iterative method and stopping rules were introduced for use in astronomical imaging. The paper begins with a brief introduction to the CT, PET, and SPECT mathematical and statistical models. The iterative method and stopping rules are then presented. And finally, numerical experiments are presented to validate the methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Applications of a Nonnegatively Constrained Iterative Method with Statistically Based Stopping

In this paper, we extend a nonnegatively constrained iterative method and three stopping rules for its iterations to the medical imaging inverse problems of computed tomography (CT), positron emission tomography (PET), and single photon emission computed tomography (SPECT); the iterative method and stopping rules were introduced for use in astronomical imaging. The paper begins with a brief int...

متن کامل

An Nonnegatively Constrained Iterative Method for Positron Emission Tomography

In positron emission tomography (PET), data is collected via the detection of photons emitted by a radioactive tracer within the subject. The noise in PET data is Poisson, and hence, it is typical to reconstruct the tracer density distribution via the computation of an approximate minimizer of the negative-log Poisson likelihood function. In this paper, we present an iterative method for the so...

متن کامل

Quantitative SPECT and planar 32P bremsstrahlung imaging for dosimetry purpose –An experimental phantom study

Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...

متن کامل

Diagnostic efficiency of 68Ga-DOTATATE PET/CT as compared to 99mTc-Octreotide SPECT/CT and conventional morphologic modalities in neuroendocrine tumors

Objective(s): In view of somatostatin receptor (SSR) expression on cell membranes of the majority of neuroendocrine tumors (NETs), functional imaging exploiting analogs of SSR alongside the anatomical imaging is the mainstay of this diagnostic modality. In this prospective study, we assessed and directly compared the diagnostic parameters of 68Ga-DOTATATE PET/CT and 99...

متن کامل

Direct comparison of 99mTc-PSMA SPECT/CT and 68Ga-PSMA PET/CT in patients with prostate cancer

Objective(s): 99mTc-PSMA SPECT/CT is a cost effective alternative for 68Ga-PSMA PET/CT. The aim of this study was to directly compare these two techniques in patients with prostate cancer. Methods: 28 man with prostate cancer were studied using 99mTc-PSMA SPECT/CT and 68Ga-PSMA PET/CT in a shor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010