Surfactant-induced electroosmotic flow in microfluidic capillaries.

نویسندگان

  • Glareh Azadi
  • Anubhav Tripathi
چکیده

Control of EOF in microfluidic devices is essential in applications such as protein/DNA sizing and high-throughput drug screening. With the growing popularity of poly(methyl methacrylate) (PMMA) as the substrate for polymeric-based microfludics, it is important to understand the effect of surfactants on EOF in these devices. In this article, we present an extensive investigation exploring changes in EOF rate induced by SDS, polyoxyethylene lauryl ether (Brij35) and CTAB in PMMA microfluidic capillaries. In a standard protein buffer (Tris-Glycine), PMMA capillaries exhibited a cathodic EOF with measured mobility of 1.54 ± 0.1 (× 10⁻⁴ cm²/V.s). In the presence of surfactant below a critical concentration, EOF was independent of surfactant concentration. At high concentrations of surfactants, the electroosmotic mobility was found to linearly increase/decrease as the logarithm of concentration before reaching a constant value. With SDS, the EOF increased by 257% (compared to buffer), while it was decreased by 238% with CTAB. In the case of Brij35, the electroosmotic mobility was reduced by 70%. In a binary surfactant system of SDS/CTAB and SDS/Brij35, addition of oppositely charged CTAB reduced the SDS-induced EOF more effectively compared to nonionic Brij35. We propose possible mechanisms that explain the observed changes in EOF and zeta potential values. Use of neutral polymer coatings in combination with SDS resulted in 50% reduction in the electroosmotic mobility with 0.1% hydroxypropyl methyl cellulose (HPMC), while including 2% poly (N,N-dimethylacrylamide) (PDMA) had no effect. These results will potentially contribute to the development of PMMA-based microfluidic devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surfactant-based methods for prevention of protein adsorption in capillary electrophoresis.

Surfactants such as didodecyldimethyl ammonium bromide (DDAB) and 1,2-dilauroyl-sn-phosphatidylcholine (DLPC) form bilayers at the walls of bare silica capillaries. Once formed, these bilayers are stable in the absence of surfactant in the buffer. DDAB provides a cationic bilayer coating which yields a strong reversed EOF and is effective for separation of cationic proteins. DLPC provides a zwi...

متن کامل

Short communication

Poly(dimethylsiloxane) (PDMS) microfluidic devices were prepared from different ratios of “curing agent” (which contains silicon hydride groups) to “base” (which contains vinyl-terminated noncross-linked PDMS), to determine the effect of this ratio on electroosmotic flow (EOF). In fabricating devices for this purpose, a novel method for permanently enclosing PDMS channels was developed. As a su...

متن کامل

Direct and indirect electroosmotic flow velocity measurements in microchannels.

As microfluidic technologies mature, increasingly complex solutions are employed, and accurate methods for the measurement of electroosmotic flow rates are becoming increasingly important. The methodologies of both a direct method and an indirect method of flow rate measurement are presented here. The direct method involves flow visualization using trace amounts of a caged fluorescent dye. The ...

متن کامل

Electroosmotic capillary flow with nonuniform zeta potential

The present work is an analytical and experimental study of electroosmotic flow (EOF) in cylindrical capillaries with nonuniform wall surface charge (zeta-potential) distributions. In particular, this study investigates perturbations of electroosmotic flow in open capillaries that are due to induced pressure gradients resulting from axial variations in the wall zeta-potential. The experimental ...

متن کامل

Effect of analyte adsorption on the electroosmotic flow in microfluidic channels.

The predictability and constancy over time of the electroosmotic flow in microchannels is an important consideration in microfluidic devices. A common cause for alteration of the flow is the adsorption of analytes to channel walls, for example, during capillary electrophoresis of proteins. It is shown that certain experimental data, published by Towns and Regnier (Towns, J. K; Regnier, F. E. An...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Electrophoresis

دوره 33 14  شماره 

صفحات  -

تاریخ انتشار 2012