Optical quality and depth-of-field of eyes implanted with spherical and aspheric intraocular lenses.

نویسندگان

  • Susana Marcos
  • Sergio Barbero
  • Ignacio Jiménez-Alfaro
چکیده

PURPOSE To compare experimental optical performance in eyes implanted with spherical and aspheric intraocular lenses (IOLs). METHODS Corneal, total, and internal aberrations were measured in 19 eyes implanted with spherical (n=9) and aspheric (n=10) IOLs. Corneal aberrations were estimated by virtual ray tracing on corneal elevation maps, and total aberrations were measured using a second-generation laser ray tracing system. Corneal and total wave aberrations were fit to a Zernike polynomial expansion. Internal aberrations were measured by subtracting corneal from total wave aberrations. Optical performance was evaluated in terms of root-mean-square (RMS) wavefront error and Strehl ratio (estimated from the modulation transfer function). Depth-of-field was obtained from through-focus Strehl estimates from each individual eye. RESULTS Corneal aberrations increased after IOL implantation, particularly astigmatism and trefoil terms. Third and higher order RMS (and the corresponding Strehl ratio) were significantly better in eyes with aspheric IOLs than with spherical IOLs; however, this tendency was reversed when astigmatism was included. Spherical aberration was not significantly different in eyes with aspheric IOLs, whereas it was significantly positive in eyes with spherical IOLs. Third order aberrations were not significantly different across groups. Depth-of-field was significantly larger in eyes with spherical IOLs. Spherical IOLs showed better absolute optical quality in the presence of negative defocus >1.00 D. CONCLUSIONS Our study shows a good degree of compensation of the corneal spherical aberration in eyes implanted with aspheric IOLs, as opposed to eyes implanted with spherical IOLs. Other sources of optical degradation, both with aspheric and spherical IOLs, are non-symmetric preoperative corneal aberrations, incision-induced aberrations, and third order internal aberrations. Although best corrected optical quality is significantly better with aspheric IOLs, tolerance to defocus tended to be lower.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extended depth of focus with induced spherical aberration in light-adjustable intraocular lenses.

PURPOSE To evaluate the quality of vision and depth of focus induced by controlled amounts of negative spherical aberration in patients implanted bilaterally with light-adjustable intraocular lenses. DESIGN Prospective, nonrandomized clinical trial. METHODS Seventeen patients were implanted and treated with appropriate spatial irradiance light profiles. One eye was set for emmetropia, and t...

متن کامل

Comparison of higher order aberrations with spherical and aspheric IOLs compared to normal phakic eyes.

PURPOSE To compare higher order aberrations (HOA) in AcrySof SN60AT and Acrysof IQ SN60WF intraocular lenses (IOLs) and natural crystalline lenses in an age-matched population. METHODS Sixty-nine eyes of 55 patients were examined. Group I included AcrySof spheric lenses, group II AcrySof aspheric lenses, and group III included patients with the natural crystalline lens. The HOA data were obta...

متن کامل

Visual outcome and optical quality after bilateral implantation of aspheric diffractive multifocal, aspheric monofocal and spherical monofocal intraocular lenses: a prospective comparison.

AIM To evaluate the visual function after bilateral implantation of aspheric diffractive multifocal Tecnis ZMA00, aspheric monofocal ZA9003 versus spherical monofocal Akreos Adapt intraocular lenses (IOLs). METHODS Tecnis ZMA00, Tecnis ZA9003 or Akreos Adapt IOLs were bilaterally implanted in 180 eyes from 90 patients. The following parameters were assessed 3 months postoperatively: monocular...

متن کامل

Customized computer models of eyes with intraocular lenses.

We compared experimental wave aberrations in pseudophakic eyes with aspheric intraocular lenses (IOLs) to simulate aberrations from numerical ray tracing on customized computer eye models using corneal topography, angle lambda, ocular biometry, IOL geometry, and IOL tilt and decentration measured on the same eyes. We found high correlations between real and simulated aberrations even for the ey...

متن کامل

Comparison of retinal image quality with spherical and customized aspheric intraocular lenses

We hypothesize that an intraocular lens (IOL) with higher-order aspheric surfaces customized for an individual eye provides improved retinal image quality, despite the misalignments that accompany cataract surgery. To test this hypothesis, ray-tracing eye models were used to investigate 10 designs of mono-focal single lens IOLs with rotationally symmetric spherical, aspheric, and customized sur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 21 3  شماره 

صفحات  -

تاریخ انتشار 2005