Nerve stimulators used for peripheral nerve blocks vary in their electrical characteristics.
نویسندگان
چکیده
BACKGROUND Nerve stimulation with a low-intensity electrical current has become a vital part of the performance of peripheral nerve blockade. The purpose of this study was to compare the accuracy and characteristics of peripheral nerve stimulators used in clinical practice in the United States. METHODS Fifteen peripheral nerve stimulators were fitted with fresh batteries and set to deliver currents ranging from 0.1 to 4.0 mA into a series of high-tolerance resistance loads ranging from 1 to 100 komega. The current output, stimulus duration, morphology, frequency, and maximum voltage output were studied using a factory-calibrated oscilloscope. RESULTS All peripheral nerve stimulators performed uniformly well when set to deliver currents of 1.0 mA or more into a standard resistance load of 1 or 2 komega. However, at lower currents, the median error (%) increased from 2.4 (-5-144%) at 0.5 mA to 10.4 (-24-180%) at 0.1 mA into a 1 komega load. The morphology of the stimulus was characterized by a regular monophasic square pulse at current outputs of up to 1 mA and at a resistance of 1 komega. The stimulus waveform became particularly distorted as the impedance load was increased. The duration of the default stimulus set by the manufacturer varied from 34.8 to 460 micros among the peripheral nerve stimulators tested. The maximum voltage output ranged from 7.4 to 336 Volts. CONCLUSIONS Nerve stimulators used for regional anesthesia vary greatly in accuracy of current output and in manufacturer-selected electrical characteristics (e.g., current duration, stimulating frequency, maximum voltage output).
منابع مشابه
Nanotechnology for peripheral nerve regeneration
Peripheral nerve injuries (PNI) can lead to lifetime loss of function and disfigurement. Different methods such as conventional allograft procedures and using of biological tubes have problems for damaged peripheral nerves reconstruction. Designed scaffolds with natural and synthetic materials are now widely used in the reconstruction of damaged tissues. Utilization of absorbable and non-absorb...
متن کاملNanotechnology for peripheral nerve regeneration
Peripheral nerve injuries (PNI) can lead to lifetime loss of function and disfigurement. Different methods such as conventional allograft procedures and using of biological tubes have problems for damaged peripheral nerves reconstruction. Designed scaffolds with natural and synthetic materials are now widely used in the reconstruction of damaged tissues. Utilization of absorbable and non-absorb...
متن کاملInterventional multispectral photoacoustic imaging with a clinical ultrasound probe for discriminating nerves and tendons: an ex vivo pilot study.
Accurate and efficient identification of nerves is an essential component of peripheral nerve blocks. While ultrasound (US) imaging is increasingly used as a guidance modality, it often provides insufficient contrast for identifying nerves from surrounding tissues such as tendons. Electrical nerve stimulators can be used in conjunction with US imaging for discriminating nerves from surrounding ...
متن کاملPHARMACOLOGICAL APPROACHES TO PAIN MANAGEMENT IN CHILDREN: Lecture: REGIONAL ANANESTHESIA: NEW DEVELOPMENTS AND IMPROVING ACCURACY
Objectives: Regional anesthesia can provide absolute pain relief without the risks of opiate induced respiratory depression. The purpose of this lecture is to provide an insight into some new techniques that (i) may improve the success and accuracy of peripheral nerve blocks, with particular reference to the role of nerve mapping, nerve stimulators and portable ultrasound; (ii) methods to prolo...
متن کاملAge-Dependent Regeneration by Using Electromyographical Study Foliowing Sciatic Nerve Injury in Rat
Purpose: There are extensive evidences that show axonal processes of the nervous system (peripheral and/or central) may be degenerated after nerve injuries. Axonal regeneration is relation to various factors. In this investigation we decided to evaluate the effects of nerve regeneration age-dependent on injured rat sciatic nerv. Materials and Methods: For this study, the right sciatic nerve of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Anesthesiology
دوره 98 4 شماره
صفحات -
تاریخ انتشار 2003