Determination of perchlorate at parts-per-billion levels in plants by ion chromatography.
نویسندگان
چکیده
A method for the analysis of perchlorate in plants was developed, based on dry weight, and applied to the analysis of plant organs, foodstuffs, and plant products. The method reduced greatly the ionic interferences in water extracts of plant materials. The high background conductivity, due to the plant matrix, was reduced sufficiently to allow quantitation of perchlorate with little or no matrix interference. Ion chromatography (IC) on a microbore AS16 anion-exchange column and a conductivity detector was used for separation and detection of perchlorate from the ionic plant extract. The extract was heated to precipitate proteins, centrifuged, exposed to alumina, and filtered through a cartridge filled with divinylbenzene to yield a water clear extract for IC analysis, even from highly colored solutions. Heating the extract and treatment with alumina reduced substantially the ionic content of the extracts without loss of perchlorate.
منابع مشابه
Determination of perchlorate at trace levels in drinking water by ion-pair extraction with electrospray ionization mass spectrometry.
Perchlorate has been added to the U.S. Environmental Protection Agency's Drinking Water Contaminant Candidate List (CCL). The present work describes the analysis of perchlorate in water by liquid-liquid extraction followed by flow injection electrospray mass spectrometry (ESI/MS). Cationic surfactants, mostly alkyltrimethyl-ammonium salts, are used to ion-pair aqueous perchlorate, forming extra...
متن کاملMicroscale extraction of perchlorate in drinking water with low level detection by electrospray-mass spectrometry.
Improper treatment and disposal of perchlorate can be an environmental hazard in regions where solid rocket motors are used, tested, or stored. The solubility and mobility of perchlorate lends itself to ground water contamination, and some of these sources are used for drinking water. Perchlorate in drinking water has been determined at sub-mug l(-1) levels by extraction of the ion-pair formed ...
متن کاملDetermination of Ultratrace Level Perchlorate in Liquid and Powdered Baby Formula
Perchlorate is a widespread contaminant in the United States.1 Research has demonstrated its presence in various media, including water, soil, various foods, and also human biological fluids, such as urine and breast milk.2-6 Perchlorate causes an adverse health effect by competitively inhibiting iodide uptake by the thyroid gland because it exhibits a much higher selectivity factor than iodide...
متن کاملQuantitation of Perchlorate Ion: Practices and Advances Applied to the Analysis of Common Matrices
In 1997, low-level perchlorate contamination (<50 ng mL–1 or parts per billion) was discovered in the western U.S. Since that time, it has been found in sites scattered around the nation. Although the Environmental Protection Agency has not established a regulation for perchlorate in drinking water, it has placed perchlorate on the contaminant candidate list (CCL) and the unregulated contaminan...
متن کاملThe Analysis of Perchlorate by Ion Chromatography/Mass Spectrometry Application
A method for the determination of perchlorate anion at sub ppb levels using ion chromatography/mass spectrometry (IC/MS) is described. The IC/MS method follows EPA Method 314 methodology originally developed for IC with conductivity detection at the single ppb range [1]. The IC/MS method is not affected by the addition of the interference matrix described in Method 314 on perchlorate recoveries...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography. A
دوره 898 2 شماره
صفحات -
تاریخ انتشار 2000