Mechanical correction of dynamometer moment for the effects of segment motion during isometric knee-extension tests.
نویسندگان
چکیده
The purpose of this study was to determine the effect of dynamometer and joint axis misalignment on measured isometric knee-extension moments using inverse dynamics based on the actual joint kinematic information derived from the real-time X-ray video and to compare the errors when the moments were calculated using measurements from external anatomical surface markers or obtained from the isokinetic dynamometer. Six healthy males participated in this study. They performed isometric contractions at 90° and 20° of knee flexion, gradually increasing to maximum effort. For the calculation of the actual knee-joint moment and the joint moment relative to the knee-joint center, determined using the external marker, two free body diagrams were used of the Cybex arm and the lower leg segment system. In the first free body diagram, the mean center of the circular profiles of the femoral epicondyles was used as the knee-joint center, whereas in the second diagram, the joint center was assumed to coincide with the external marker. Then, the calculated knee-joint moments were compared with those measured by the dynamometer. The results indicate that 1) the actual knee-joint moment was different from the dynamometer recorded moment (difference ranged between 1.9% and 4.3%) and the moment calculated using the skin marker (difference ranged between 2.5% and 3%), and 2) during isometric knee extension, the internal knee angle changed significantly from rest to the maximum contraction state by about 19°. Therefore, these differences cannot be neglected if the moment-knee-joint angle relationship or the muscle mechanical properties, such as length-tension relationship, need to be determined.
منابع مشابه
The Relationship Between Muscle Strength and Range of Motion in Lower Extremity, and Balance and Risk of Falling in the Elderly
Background: The present study examined the relationship between muscle strength and range of motion in the lower extremity, and balance and risk of falling in the elderly. Methods: This cross-sectional study was conducted on healthy elderly (mean±SD age: 65.64±4.95 y) in Rasht City, Iran. The study participants were 65 healthy male elderly who met the stud inclusion criteria. They were selecte...
متن کاملEffects of trunk stability on isometric knee extension muscle strength measurement while sitting
[Purpose] This study aimed to investigate the effect of trunk stability on isometric knee extension muscle strength measurement while sitting by performing simultaneous measurements with a handheld dynamometer (HHD) and an isokinetic dynamometer (IKD) in the same seated condition. [Subjects and Methods] The subjects were 30 healthy volunteers. Isometric knee extension muscle strength was simult...
متن کاملبررسی تغییرات کنترل حرکت در انجام حرکت فلکشن و اکستنشن ستون فقرات کمری به دنبال استفاده از حمایت کنندههای کمری - خاجی
Background: The changes in motor control after the use of a supportive belt can contribute to the understanding of its effects on performance. The aim of this study is to quantify motion pattern values relative to the spinal column during the use of a lumbosacral belt.Methods: For fifty healthy female volunteers, the range of motion, maximum isometric torque and changes of phase angle of maximu...
متن کاملEffects of backward gait training protocol on knee adduction moment and impulse during walking in patients with medial knee osteoarthritis
Background and Aim: The aim of this study was to investigate the effects of backward gait training protocol on knee adduction moment and impulse in male patients with medial knee osteoarthritis. Materials and Methods: This quasi-experimental study with a pretest-posttest design included two control groups (healthy and patient) and an experimental group (subjects with medial knee osteoarthritis)...
متن کاملDesign and construction of 6-component balance dynamometer for measurement of the forces, moments andmotions of ship models in the towing tank
During design spiral of a merchant ship or a naval vessel, it is important to perform towing tank tests in order to measure its performance either in calm water maneuvers or in waves for seakeeping performance. Also, to optimize a hydrodynamic design, towing tank tests are advantageous.This article presents the results of an applied research project. The objective of this project is to design a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 111 1 شماره
صفحات -
تاریخ انتشار 2011