Tissue reaction around loosened prostheses: a histological, X-ray microanalytic and immunological study.
نویسندگان
چکیده
Tissue reactions at the cement-bone and artificial implant-bone interface were examined light and electron microscopically in thirty-six patients who underwent revisory operation of hip or knee replacement. The reactions were classified into three types: inert tissue, active tissue with giant cell proliferation, and active tissue with predominant foamy cell proliferation. The third type of reaction was found only in total hip replacement with bone cement. No evidence of allergic reaction to implanted materials was found in any replacement, though active cellular infiltrations were observed around loosened prostheses especially in cemented arthroplasty. The tissue reactions always occurred around instable or loosened prostheses. Thus, the present study shows that mechanical instability is the primary cause of such undesired tissue reactions.
منابع مشابه
Gene therapy and cement injection for restabilization of loosened hip prostheses.
Loosening of orthopedic hip prostheses is an increasing health problem. In elderly patients with comorbidity,revision surgery may lead to high mortality rates. A less invasive surgical technique is therefore required to reduce these patient risks. To this end a percutaneous gene therapy approach was designed to destroy the periprosthetic loosening membrane, and enable refixing of the hip prosth...
متن کاملNecrobiosis and T-lymphocyte infiltration in retrieved aseptically loosened metal-on-polyethylene arthroplasties
BACKGROUND AND PURPOSE Soft tissue necrobiosis and T-lymphocyte infiltration within the periprosthetic soft tissue have been linked to a suggested hypersensitivity reaction of the delayed-type following the metal-on-metal arthroplasty. While we observed both synovial necrobiosis and lymphocyte infiltrates in synovial tissues with failed metal-on-polyethylene prostheses, we hypothesized that bot...
متن کاملOn stabilization of loosened hip stems via cement injection into osteolytic cavities.
BACKGROUND Cement injection into osteolytic areas around the cement mantle is a technique for refixation of loose hip implants for patients who cannot undergo standard revision surgery. Preliminary clinical results show the improvement in walking distance, patients' independence and pain relief. METHODS In this study, we use a detailed finite element model to analyze whether cement injection ...
متن کاملAcidosis, osteoclast formation and cathepsin K expression in the loosening of total hip prostheses
and The National Graduate School for Biomaterials and Tissue Engineering ACADEMIC DISSERTATION To be publicly discussed with the permission of the Medical Faculty of the University of Helsinki, in the large lecture hall (Iso luentosali) Work hard and try your best! If you then fail I am not angry.-my father-This thesis is based on the following original publications. They are referred to in the...
متن کاملExpression of parathyroid hormone related protein in the tissue around loosened hip prostheses.
OBJECTIVE To investigate the eventual presence and cellular source ofparathyroid hormone related protein (PTHrP) in the synovial-like interface membrane from aseptic loosening of total hip replacement (THR). METHODS A polyclonal rabbit antiserum to the amino-terminal peptide of human PTHrP was used to stain 10 interface membrane samples from loose THR and 10 synovial tissue samples from hip o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta medica Okayama
دوره 40 5 شماره
صفحات -
تاریخ انتشار 1986