The effect of brushing motion on the cyclic fatigue of rotary nickel titanium instruments.
نویسندگان
چکیده
The goal of the study is to evaluate if the use of rotary nickel-titanium (RNT) instruments, as Hedstroem files, is safe. Twelve twisted files (TF) RNT instruments size 06-25 were selected and randomly divided in 2 groups of 6 instruments each. Group A (new instruments) were used as control. Group B (test) instruments were clinically used only as Hedstroem files in a canal that had been previously instrumented to the working length with other 06-25 RNT instruments. Group B instruments were used only in the straight portion of the canal (1 minute at 1000 rpm). A cyclic fatigue test was performed for each instrument of groups. Data were statistically analyzed (Student's t-test). Results showed no significant difference (P > 0.05) between groups A and B. Data confirmed that the use of TF instruments as Hedstroem files is a safe procedure. Cross section images and volumes of the same instrument, before and after cyclic fatigue testing, have been obtained by means of microtomographic analysis to evaluate possible microstructure alterations.
منابع مشابه
Deformations and cyclic fatigue resistance of nickel-titanium instruments inside a sequence.
AIM To compare the effect of brushing motion on torsional and cyclic fatigue resistance of TF Adaptive instruments after clinical use. METHODS 20 packs of TFA small sequence (SybronEndo, Orange, CA, USA) were used for this study and divided into two groups. Each instrument prepared one resin tooth, consisting in 4 canals with a complex anatomy. In group A, no brushing motion was performed. In...
متن کاملFracture resistance of electropolished rotary nickel-titanium endodontic instruments.
The purpose of this study was to investigate the effect of electropolishing on cyclic flexural fatigue and torsional strength of rotary nickel-titanium endodontic instruments. Electropolished and nonelectropolished ISO size 30 (0.04 taper) EndoWave (J Morita Corporation, Osaka, Japan), ProFile (Dentsply Maillefer, Ballaigues, Switzerland), and RaCe (FKG, La-Chaux De Fonds, Switzerland) instrume...
متن کاملCyclic Fatigue of Different Nickel-Titanium Rotary Instruments: A Comparative Study
Since the introduction of nickel-titanium alloy to endodontics, there have been many changes in instrument design, but no significant improvements in the raw material properties, or enhancements in the manufacturing process. Recently, a new method to produce nickel-titanium rotary (NTR) instruments has been developed, in an attempt to obtain instruments that are more flexible and resistant to f...
متن کاملEffect of clinical use on the cyclic fatigue resistance of ProTaper nickel-titanium rotary instruments.
The resistance of ProTaper (Dentsply Maillefer, Ballaigues, Switzerland) nickel-titanium rotary instruments to cyclic fatigue was examined after their initial use in straight or curved canals in vivo. These instruments were rotated freely inside a steel phantom until separation. The number of rotations before failure and the lengths of the separated fragments were compared with data derived fro...
متن کاملCyclic fatigue testing of nickel-titanium endodontic instruments.
Cyclic fatigue of nickel-titanium, engine-driven instruments was studied by determining the effect of canal curvature and operating speed on the breakage of Lightspeed instruments. A new method of canal curvature evaluation that addressed both angle and abruptness of curvature was introduced. Canal curvature was simulated by constructing six curved stainless-steel guide tubes with angles of cur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annali dell'Istituto superiore di sanita
دوره 46 4 شماره
صفحات -
تاریخ انتشار 2010