Variable frequency transformer (VFT), introduced recently is a flexible asynchronous ac link which is used in power transferal process between asynchronous power system grids. VFT was first installed at Langlois substation, which interconnects the Hydro-Québec (Canada) and New York (USA) systems. The torque of the rotary transformer is externally altered in order to control the direction and magnitude of power transfer. MATLAB Simulink model of VFT is designed, which is used to indicate power transmission between two asynchronous grids and also to control the power flow direction. MATLAB Simulink model of VFT along with its control system is developed and the result has been studied thoroughly. Simulation results for different torque and frequency conditions have been discussed. Moving further, power transfer and torque graphical representations are also obtained and results are compared. Thus, the working concept of VFT and its power flow conditions are verified by MATLAB simulation results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Brushless Doubly-Fed Induction Machine as a Variable Frequency Transformer

VFT (variable frequency transformer) has been recently used as an alternative to HVDC (high voltage direct current) to control power flow between asynchronous networks. VFT consumes less reactive power than a back-to-back HVDC system, provides faster initial transient recovery, and has better natural damping capability. VFT is simply a DFIM (doubly-fed induction machine) where the machine torqu...

متن کامل

Grid File Transfer During Deployment, Execution, and Retrieval

We propose a file transfer approach for the Grid. We have identified that file transfer in the Grid can take place at three different stages: deployment, user application execution, and retrieval (postexecution). Each stage has different environmental requirements, and therefore we apply different techniques. Our contribution comes from: (i) integrating heterogeneous Grid resource acquisition p...

متن کامل

Molecular determinants involved in the allosteric control of agonist affinity in the GABAB receptor by the GABAB2 subunit.

The gamma-aminobutyric acid type B (GABAB) receptor is an allosteric complex made of two subunits, GABAB1 (GB1) and GABAB2 (GB2). Both subunits are composed of an extracellular Venus flytrap domain (VFT) and a heptahelical domain (HD). GB1 binds GABA, and GB2 plays a major role in G-protein activation as well as in the high agonist affinity state of GB1. How agonist affinity in GB1 is regulated...

متن کامل

Modeling and Control for Smart Grid Integration with MPPT of Solar/Wind Energy Conversion System

Performance optimization, system reliability and operational efficiency are key characteristics of smart grid systems. In this paper a novel model of smart grid-connected PV/WT hybrid system is developed. It comprises photovoltaic array, wind turbine, asynchronous (induction) generator, controller and converters. The model is implemented using MATLAB/SIMULINK software package. Perturb and obser...

متن کامل

Low-Speed Sensorless Control of DFIG Generators Drive for Wind Turbines System

In this paper, we present a nonlinear robust control of active and reactive power by the use the PI regulators control (FOC) a Double-Fed Asynchronous Generator (DFIG) system incorporated in a windturbine. The power transfer between the stator and the network grid is carried out by acting on the rotor via a bidirectional signal converter. Initially, a control strategy of the MPPT-DFIG is presen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017